Occlusal interferences and cantilever joint stress in implant-supported prostheses occluding with complete dentures
- PMID: 2391138
Occlusal interferences and cantilever joint stress in implant-supported prostheses occluding with complete dentures
Abstract
Naturally occurring closing and chewing forces were measured in dentitions with mandibular fixture-supported bilateral distal two-unit cantilever fixed prostheses occluding with complete dentures, and the vertical bending stress in the cantilever joint of the preferred chewing side was assessed. Occlusal forces were measured using eight miniature strain gauge transducers bilaterally and symmetrically mounted in complete dentures. Occlusal forces over the entire prosthesis were registered in basic (habitual) occlusion and with a 100-microns-high premature occlusal contact on the second cantilever unit. Closing and chewing forces increased distally. The premature occlusal contact did not significantly influence the total forces over the entire dentition but increased the local forces over the second cantilever unit. The group mean maximal vertical bending stress for closing forces reached the fatigue limit for unhardened type III dental gold alloy in basic occlusion. Although the interfered occlusion resulted in a significant redistribution of forces and significantly altered the stress contributions from each cantilever unit, maximal vertical bending stress in the cantilever joint was not significantly influenced. During chewing, the fatigue limit was not reached in basic or in interfered occlusion.
Similar articles
-
On occlusal forces in dentitions with implant-supported fixed cantilever prostheses.Swed Dent J Suppl. 1990;69:1-40. Swed Dent J Suppl. 1990. PMID: 2196708
-
Influence of number and distribution of occlusal cantilever contacts on closing and chewing forces in dentitions with implant-supported fixed prostheses occluding with complete dentures.Int J Oral Maxillofac Implants. 1989 Winter;4(4):277-83. Int J Oral Maxillofac Implants. 1989. PMID: 2639855
-
Occlusal force pattern in dentitions with mandibular implant-supported fixed cantilever prostheses occluded with complete dentures.Int J Oral Maxillofac Implants. 1989 Spring;4(1):55-62. Int J Oral Maxillofac Implants. 1989. PMID: 2689336
-
An overview of complete artificial fixed dentition supported by endosseous implants.Artif Organs. 2005 Jan;29(1):73-81. doi: 10.1111/j.1525-1594.2004.29009.x. Artif Organs. 2005. PMID: 15644087 Review.
-
The incomprehensible success of the implant stabilised overdenture in the edentulous mandible: a literature review on transfer of chewing forces to bone surrounding implants.Eur J Prosthodont Restor Dent. 1995 Dec;3(6):255-61. Eur J Prosthodont Restor Dent. 1995. PMID: 8603169 Review.
Cited by
-
Dental occlusion: modern concepts and their application in implant prosthodontics.Odontology. 2009 Jan;97(1):8-17. doi: 10.1007/s10266-008-0096-x. Epub 2009 Jan 29. Odontology. 2009. PMID: 19184293 Review.
-
Comparative three-dimensional finite element analysis of implant-supported fixed complete arch mandibular prostheses in two materials.J Indian Prosthodont Soc. 2017 Jul-Sep;17(3):255-260. doi: 10.4103/jips.jips_11_17. J Indian Prosthodont Soc. 2017. PMID: 28936039 Free PMC article.
-
Effect of the number of abutments on biomechanics of Branemark prosthesis with straight and tilted distal implants.J Appl Oral Sci. 2010 Mar-Apr;18(2):178-85. doi: 10.1590/s1678-77572010000200013. J Appl Oral Sci. 2010. PMID: 20485930 Free PMC article.
-
Biomechanical considerations on tooth-implant supported fixed partial dentures.J Dent Biomech. 2012;3:1758736012462025. doi: 10.1177/1758736012462025. Epub 2012 Oct 29. J Dent Biomech. 2012. PMID: 23255882 Free PMC article.