Which is the best tissue valve used in the pulmonary position, late after previous repair of tetralogy of Fallot?
- PMID: 23929900
- PMCID: PMC3805211
- DOI: 10.1093/icvts/ivt332
Which is the best tissue valve used in the pulmonary position, late after previous repair of tetralogy of Fallot?
Abstract
A best evidence topic in cardiac surgery was written according to a structured protocol. The question addressed was: which is the best tissue valve for use in the pulmonary position, late after previous repair of tetralogy of Fallot? Altogether 141 papers were found using the reported search, of which 13 represented the best evidence to answer the clinical question. In addition to this, 1 paper was found by searching the reference lists of the relevant papers. The authors, journal, date and country of publication, patient group studied, study type, relevant outcomes and results of these papers are tabulated. We conclude from the best evidence available that homograft valves function well in the pulmonary position late after Tetralogy of Fallot (TOF) repair. This is particularly evident in the larger studies where the patients were only treated with homografts. It has been suggested that Homografts are better than xenografts and this has not been statistically shown. Two articles have suggested that xenografts outperform homografts however, in both studies these results were not statistically significant. Furthermore, early indications suggest that porcine valves may be better than bovine pericardial valves but a better longer term follow-up is certainly required to demonstrate this. It is important to realize also that when comparing the effectiveness of these valves in the pulmonary position, one cannot ignore confounding factors. The most important of these include timing of operation, age of patient, valve size, immunological factors, operative complexity and also postoperative valvular gradients. The timing of these operations has always been an area of great controversy illustrated by varied guidelines. There is no general consensus regarding whether there is even a role of pulmonary valve replacement late after TOF repair. Further weakening any conclusions that may be drawn based on current best evidence is the lack of strong follow-up data (transvalvular gradients and right ventricular (RV) volumetric data). New research is required with comparisons using objective clinical parameters in order to more effectively answer our clinical question.
Keywords: Bovine pericardial; Complication; Durability; Homograft; Mortality; Outcome; Porcine; Pulmonary valve replacement; Survival; Tetralogy of Fallot; Xenograft.
Comment in
-
eComment. Transcatheter heart valve in the pulmonary position.Interact Cardiovasc Thorac Surg. 2013 Nov;17(5):860. doi: 10.1093/icvts/ivt404. Interact Cardiovasc Thorac Surg. 2013. PMID: 24150055 Free PMC article. No abstract available.
Similar articles
-
Is there a role for mechanical valve prostheses in pulmonary valve replacement late after tetralogy of Fallot repair?Interact Cardiovasc Thorac Surg. 2014 May;18(5):661-6. doi: 10.1093/icvts/ivt541. Epub 2014 Jan 30. Interact Cardiovasc Thorac Surg. 2014. PMID: 24480820 Review.
-
Investigating the Long-term Durability of Prosthetic Valves in Patients Who Have Undergone Tetralogy of Fallot Surgery with Transannular Patch.Interdiscip Cardiovasc Thorac Surg. 2025 Aug 5;40(8):ivaf159. doi: 10.1093/icvts/ivaf159. Interdiscip Cardiovasc Thorac Surg. 2025. PMID: 40613688 Free PMC article.
-
Pulmonary valve replacement long after repair of tetralogy of Fallot.Gen Thorac Cardiovasc Surg. 2012 Jun;60(6):341-4. doi: 10.1007/s11748-012-0056-9. Epub 2012 May 8. Gen Thorac Cardiovasc Surg. 2012. PMID: 22566262
-
Does pulmonary valve replacement post repair of tetralogy of Fallot improve right ventricular function?Interact Cardiovasc Thorac Surg. 2009 Sep;9(3):520-7. doi: 10.1510/icvts.2009.211011. Epub 2009 Jun 30. Interact Cardiovasc Thorac Surg. 2009. PMID: 19567499 Review.
-
What type of valve is most appropriate for osteogenesis imperfecta patients?Interact Cardiovasc Thorac Surg. 2014 Sep;19(3):499-504. doi: 10.1093/icvts/ivu152. Epub 2014 May 29. Interact Cardiovasc Thorac Surg. 2014. PMID: 24876219 Review.
Cited by
-
Resting heart rate influences right ventricular volume in repaired tetralogy of Fallot.Pediatr Cardiol. 2015 Apr;36(4):813-20. doi: 10.1007/s00246-014-1088-y. Epub 2014 Dec 20. Pediatr Cardiol. 2015. PMID: 25527228
-
Trifecta St. Jude medical® aortic valve in pulmonary position.Nano Rev Exp. 2017 May 1;8(1):1299900. doi: 10.1080/20022727.2017.1299900. eCollection 2017. Nano Rev Exp. 2017. PMID: 30410702 Free PMC article.
-
Reversal of Right Ventricular Remodeling After Correction of Pulmonary Regurgitation in Tetralogy of Fallot.JACC Basic Transl Sci. 2022 Dec 14;8(3):301-315. doi: 10.1016/j.jacbts.2022.09.008. eCollection 2023 Mar. JACC Basic Transl Sci. 2022. PMID: 37034286 Free PMC article.
-
Next-generation transcatheter aortic valve implantation.JTCVS Open. 2020 Jun 24;3:14-24. doi: 10.1016/j.xjon.2020.06.008. eCollection 2020 Sep. JTCVS Open. 2020. PMID: 36003870 Free PMC article.
-
Pulmonary valve replacement after repaired Tetralogy of Fallot.Gen Thorac Cardiovasc Surg. 2018 Sep;66(9):509-515. doi: 10.1007/s11748-018-0931-0. Epub 2018 May 19. Gen Thorac Cardiovasc Surg. 2018. PMID: 29779123 Review.
References
-
- Dunning J, Prendergast B, Mackway-Jones K. Towards evidence based medicine in cardiothoracic surgery: best BETS. Interact CardioVasc Thoracic Surg. 2003;2:405–9. - PubMed
-
- Oosterhof T, van Straten A, Vliegen H, Meijboom F, van Dijk A, Spijkerboer AM, et al. Preoperative thresholds for pulmonary valve replacement in patients with corrected tetralogy of Fallot using cardiovascular magnetic resonance. Circulation. 2007;116:545–51. - PubMed
-
- Discigil B, Dearani J, Puga F, Schaff HV, Hagler DJ, Warnes CA, et al. Late pulmonary valve replacement after repair of tetralogy of Fallot. J Thorac Cardiovasc Surg. 2001;121:344–51. - PubMed
-
- Warner KG, O'Brien PK, Rhodes J, Kaur A, Robinson DA, Payne DD. Expanding the indications for pulmonary valve replacement after repair of tetralogy of fallot. Ann Thorac Surg. 2003;76:1066–71. - PubMed
-
- Shiokawa Y, Sonoda H, Tanoue Y, Nishida T, Nakashima A, Tominaga R. Pulmonary valve replacement long after repair of tetralogy of Fallot. Gen Thorac Cardiovasc Surg. 2012;60:341–4. - PubMed
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical