Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Multicenter Study
. 2014 Apr;17(2):316-23.
doi: 10.1007/s10120-013-0285-3. Epub 2013 Aug 10.

High false-negative proportion of intraoperative histological examination as a serious problem for clinical application of sentinel node biopsy for early gastric cancer: final results of the Japan Clinical Oncology Group multicenter trial JCOG0302

Affiliations
Multicenter Study

High false-negative proportion of intraoperative histological examination as a serious problem for clinical application of sentinel node biopsy for early gastric cancer: final results of the Japan Clinical Oncology Group multicenter trial JCOG0302

Isao Miyashiro et al. Gastric Cancer. 2014 Apr.

Abstract

Background: To evaluate the feasibility and accuracy of diagnosis using sentinel node (SN) biopsy in T1 gastric cancer, a multicenter trial was conducted by the Japan Clinical Oncology Group (JCOG).

Methods: Sentinel node biopsy with indocyanine green (ICG) was performed in patients with T1 gastric cancer. Green-stained nodes (GNs), representing SNs, were removed first, and gastrectomy with lymphadenectomy was then performed. GNs in one plane (with the largest dimension) were histologically examined intraoperatively by frozen section with hematoxylin and eosin (H&E) stain. All harvested lymph nodes (GNs and non-GNs) were histologically examined by paraffin section after surgery. The primary endpoint was to determine the proportion of false negatives, which was defined as the number of patients with negative GNs by frozen section divided by those with positive GNs and/or positive non-GNs by paraffin section. The sample size was set at 1,550, based on the expected and threshold value as 5 and 10 % in the proportion of false negatives.

Results: Accrual was suspended when 440 patients were enrolled because the proportion of false negatives was high. In the primary analysis, the proportion of false negatives was 46 % (13/28) after a learning period with 5 patients for each institution. Seven of 13 patients had nodal metastases outside the lymphatic basin. False negatives remained at 14 % (4/28) even by examining additional sections of GNs by paraffin section.

Conclusions: The proportion of false negatives was much higher than expected. Intraoperative histological examination using only one plane is not an appropriate method for clinical application of SN biopsy in gastric cancer surgery.

PubMed Disclaimer

References

    1. Ann Surg Oncol. 2013 Feb;20(2):542-6 - PubMed
    1. Clin Sci. 1961 Aug;21:43-57 - PubMed
    1. Dig Surg. 2008;25(2):103-8 - PubMed
    1. Am J Surg. 2003 Mar;185(3):202-10 - PubMed
    1. J Surg Oncol. 2009 Mar 1;99(3):137-42 - PubMed

Publication types

MeSH terms

Substances

LinkOut - more resources