System identification of evoked mechanomyogram from abductor pollicis brevis muscle in isometric contraction
Abstract
The purpose of this study is to verify the applicability of a sixth-order model to the mechanomyogram (MMG) system of the parallel-fibered muscle, which was identified from the MMG of the pennation muscle. The median nerve was stimulated, and an MMG and torque of the abductor pollicis brevis muscle were measured. The MMGs were detected with either a capacitor microphone or an acceleration sensor. The transfer functions between stimulation and the MMG and between stimulation and torque were identified by the singular value decomposition method. The torque and the MMG, which were detected with a capacitor microphone, DMMG, were approximated with a second- and a third-order model, respectively. The natural frequency of the torque, reflecting longitudinal mechanical characteristics, did not show a significant difference from that of the DMMG. The MMG detected with an acceleration sensor was approximated with a fourth-order model. The natural frequencies of the AMMG reflecting the muscle and subcutaneous tissue in the transverse direction were obtained. Both DMMG and AMMG have to be measured to investigate the model of the MMG system for parallel-fibered muscle. The MMG system of parallel-fibered muscle was also modeled with a sixth-order model.
Similar articles
-
Comparison of displacement and acceleration transducers for the characterization of mechanics of muscle and subcutaneous tissues by system identification of a mechanomyogram.Med Biol Eng Comput. 2013 Feb;51(1-2):165-73. doi: 10.1007/s11517-012-0981-x. Epub 2012 Nov 3. Med Biol Eng Comput. 2013. PMID: 23129101 Clinical Trial.
-
System identification of velocity mechanomyogram measured with a capacitor microphone for muscle stiffness estimation.J Electromyogr Kinesiol. 2017 Apr;33:57-63. doi: 10.1016/j.jelekin.2017.01.009. Epub 2017 Feb 1. J Electromyogr Kinesiol. 2017. PMID: 28192717
-
Torque and mechanomyogram relationships during electrically-evoked isometric quadriceps contractions in persons with spinal cord injury.Med Eng Phys. 2016 Aug;38(8):767-75. doi: 10.1016/j.medengphy.2016.05.012. Epub 2016 Jun 8. Med Eng Phys. 2016. PMID: 27289541
-
System identification of mechanomyograms detected with an acceleration sensor and a laser displacement meter.Annu Int Conf IEEE Eng Med Biol Soc. 2011;2011:7131-4. doi: 10.1109/IEMBS.2011.6091802. Annu Int Conf IEEE Eng Med Biol Soc. 2011. PMID: 22255982
-
A systematic review of muscle activity assessment of the biceps brachii muscle using mechanomyography.J Musculoskelet Neuronal Interact. 2018 Dec 1;18(4):446-462. J Musculoskelet Neuronal Interact. 2018. PMID: 30511949 Free PMC article.
Cited by
-
Assessment of muscle activity using electrical stimulation and mechanomyography: a systematic review.Biomed Eng Online. 2021 Jan 3;20(1):1. doi: 10.1186/s12938-020-00840-w. Biomed Eng Online. 2021. PMID: 33390158 Free PMC article.
-
Evidence towards improved estimation of respiratory muscle effort from diaphragm mechanomyographic signals with cardiac vibration interference using sample entropy with fixed tolerance values.PLoS One. 2014 Feb 19;9(2):e88902. doi: 10.1371/journal.pone.0088902. eCollection 2014. PLoS One. 2014. PMID: 24586436 Free PMC article.
-
Scaling Relationship of In Vivo Muscle Contraction Strength of Rabbits Exposed to High-Frequency Nanosecond Pulse Bursts.Technol Cancer Res Treat. 2018 Jan 1;17:1533033818788078. doi: 10.1177/1533033818788078. Technol Cancer Res Treat. 2018. PMID: 30012058 Free PMC article.
References
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources