Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2014 Jan;35(2):86-97.
doi: 10.1093/eurheartj/eht267. Epub 2013 Aug 8.

Epicardial wave mapping in human long-lasting persistent atrial fibrillation: transient rotational circuits, complex wavefronts, and disorganized activity

Affiliations

Epicardial wave mapping in human long-lasting persistent atrial fibrillation: transient rotational circuits, complex wavefronts, and disorganized activity

Geoffrey Lee et al. Eur Heart J. 2014 Jan.

Abstract

Objectives: To characterize the nature of atrial fibrillation (AF) activation in human persistent AF (PerAF) using modern tools including activation, directionality analyses, complex-fractionated electrogram, and spectral information.

Background: The mechanism of PerAF in humans is uncertain.

Methods and results: High-density epicardial mapping (128 electrodes/6.75 cm(2)) of the posterior LA wall (PLAW), LA and RA appendage (LAA, RAA), and RSPV-LA junction was performed in 18 patients with PerAF undergoing open heart surgery. Continuous 10 s recordings were analysed offline. Activation patterns were characterized into four subtypes (i) wavefronts (broad or multiple), (ii) rotational circuits (≥2 rotations of 360°), (iii) focal sources with centrifugal activation of the entire mapping area, or (iv) disorganized activity [isolated chaotic activation(s) that propagate ≤3 bipoles or activation(s) that occur as isolated beats dissociated from the activation of adjacent bipole sites]. Activation at a total of 36 regions were analysed (14 PLAW, 3 RSPV-LA, 12 LAA, and 7 RAA) creating a database of 2904 activation patterns. In the majority of maps, activation patterns were highly heterogeneous with multiple unstable activation patterns transitioning from one to another during each recording. A mean of 3.8 ± 1.6 activation subtypes was seen per map. The most common patterns seen were multiple wavefronts (56.2 ± 32%) and disorganized activity (24.2 ± 30.3%). Only 2 of 36 maps (5.5%) showed a single stable activation pattern throughout the 10-s period. These were stable planar wavefronts. Three transient rotational circuits were observed. Two of the transient circuits were located in the posterior left atrium, while the third was located on the anterior surface of the LAA. Focal activations accounted for 11.3 ± 14.2% of activations and were all short-lived (≤2 beats), with no site demonstrating sustained focal activity.

Conclusion: Human long-lasting PerAF is characterized by heterogeneous and unstable patterns of activation including wavefronts, transient rotational circuits, and disorganized activity.

Keywords: Atrial fibrillation.

PubMed Disclaimer

Comment in

  • Rotors during AF: drivers or bystanders?
    Allessie M, de Groot N. Allessie M, et al. Eur Heart J. 2014 Jan;35(2):63-5. doi: 10.1093/eurheartj/eht370. Epub 2013 Oct 2. Eur Heart J. 2014. PMID: 24092245 No abstract available.

Publication types