. 2013 Jun;5(Suppl 1):S113-6.
doi: 10.4103/0975-7406.113309.

Interactions between magnetic resonance imaging and dental material

Affiliations

Interactions between magnetic resonance imaging and dental material

Chalakuzhiyl Abraham Mathew et al. J Pharm Bioallied Sci. 2013 Jun.

Abstract

Magnetic resonance imaging (MRI) has become a common and important life-saving diagnostic tool in recent times, for diseases of the head and neck region. Dentists should be aware of the interactions of various restorative dental materials and different technical factors put to use by an MRI scanning machine. Specific knowledge about these impacts, at the dentist level and at the level of the personnel at the MRI centers can save valuable time for the patient and prevent errors in MRI images. Artifacts from metal restorations are a major hindrance at such times, as they result in disappearance or distortion of the image and loss of important information.

Keywords: Magnetic; magnetic resonance image; magnetic resonance imaging; metal artifacts.

PubMed Disclaimer

Conflict of interest statement

Conflict of Interest: None declared.

References

    1. Baek CH, Chung MK, Son YI, Choi JY, Kim HJ, Yim YJ, et al. Tumor volume assessment by 18F-FDG PET/CT in patients with oral cavity cancer with dental artifacts on CT or MR images. J Nucl Med. 2008;49:1422–8. - PubMed
    1. Taniyama T, Sohmura T, Etoh T, Aoki M, Sugiyama E, Takahashi J. Metal artifacts in MRI from non-magnetic dental alloy and its FEM analysis. Dent Mater J. 2010;29:297–302. - PubMed
    1. Shellock FG, Crues JV. High-field-strength MR imaging and metallic biomedical implants: An ex vivo evaluation of deflection forces. AJR Am J Roentgenol. 1988;151:389–92. - PubMed
    1. Shellock FG. MR imaging of metallic implants and materials: A compilation of the literature. AJR Am J Roentgenol. 1988;151:811–4. - PubMed
    1. Gegauff AG, Laurell KA, Thavendrarajah A, Rosenstiel SF. A potential MRI hazard: Forces on dental magnet keepers. J Oral Rehabil. 1990;17:403–10. - PubMed