Accurate alignment and high function after kinematically aligned TKA performed with generic instruments
- PMID: 23948721
- DOI: 10.1007/s00167-013-2621-x
Accurate alignment and high function after kinematically aligned TKA performed with generic instruments
Abstract
Purpose: Performing kinematically aligned total knee arthroplasty (TKA) with generic instruments is less costly than patient-specific instrumentation; however, the alignment and function with this new technique are unknown.
Methods: One hundred and one consecutive patients (101 knees) treated with kinematically aligned TKA, implanted with use of generic instruments, were prospectively followed. The medial collateral ligament was not released. The lateral collateral ligament was released in the 17 % of patients with a fixed valgus deformity. Six measures of alignment were categorized from a scanogram of the extremity, an axial scan of the knee, and an intraoperative measurement. Both the Oxford Knee and WOMAC™ scores were assessed as function. High function was a mean Oxford Knee score >41.
Results: The frequency that patients were categorized as in-range was 93 % for the mechanical alignment of the limb (0° ± 3°), 94 % for the joint line (-3° ± 3°), 57 % for the anatomic axis of the knee (-2.5° ± -7.4° valgus), 4 % for the varus-valgus rotation of the tibial component (≤0° valgus), 98 % for the rotation of the tibial component with respect to the femoral component (0° ± 10°), and 94 % for the intraoperative change in the anterior-posterior distance of the tibia with respect to the femur at 90° of flexion (0 ± 2 mm). The mean OKS score was 42, and WOMAC™ score was 89. For each alignment, the function was the same for patients categorized as an outlier or in-range.
Conclusions: The authors prefer the use of generic instruments to perform kinematically aligned TKA in place of mechanically aligned TKA because five of six alignments were accurate and because high function was restored regardless of whether patients had an alignment categorized as an outlier or in-range.
Level of evidence: IV.
Similar articles
-
Does a kinematically aligned total knee arthroplasty restore function without failure regardless of alignment category?Clin Orthop Relat Res. 2013 Mar;471(3):1000-7. doi: 10.1007/s11999-012-2613-z. Epub 2012 Sep 21. Clin Orthop Relat Res. 2013. PMID: 22996362 Free PMC article.
-
Centre of the posterior cruciate ligament and the sulcus between tubercle spines are reliable landmarks for tibial component placement.Knee Surg Sports Traumatol Arthrosc. 2013 Oct;21(10):2384-91. doi: 10.1007/s00167-012-2120-5. Epub 2012 Jul 3. Knee Surg Sports Traumatol Arthrosc. 2013. PMID: 22751944 Clinical Trial.
-
Do varus or valgus outliers have higher forces in the medial or lateral compartments than those which are in-range after a kinematically aligned total knee arthroplasty? limb and joint line alignment after kinematically aligned total knee arthroplasty.Bone Joint J. 2017 Oct;99-B(10):1319-1328. doi: 10.1302/0301-620X.99B10.BJJ-2017-0066.R1. Bone Joint J. 2017. PMID: 28963153
-
Does Malrotation of the Tibial and Femoral Components Compromise Function in Kinematically Aligned Total Knee Arthroplasty?Orthop Clin North Am. 2016 Jan;47(1):41-50. doi: 10.1016/j.ocl.2015.08.006. Orthop Clin North Am. 2016. PMID: 26614919 Review.
-
Kinematically Aligned Total Knee Arthroplasty Using Calipered Measurements, Manual Instruments, and Verification Checks.2020 Jul 1. In: Rivière C, Vendittoli PA, editors. Personalized Hip and Knee Joint Replacement [Internet]. Cham (CH): Springer; 2020. Chapter 24. 2020 Jul 1. In: Rivière C, Vendittoli PA, editors. Personalized Hip and Knee Joint Replacement [Internet]. Cham (CH): Springer; 2020. Chapter 24. PMID: 33347137 Free Books & Documents. Review.
Cited by
-
Mechanical Alignment in Total Knee Arthroplasty for Varus Knee Osteoarthritis Leads to Significant Tibial Bone Loss.Cureus. 2022 Oct 9;14(10):e30107. doi: 10.7759/cureus.30107. eCollection 2022 Oct. Cureus. 2022. PMID: 36381802 Free PMC article.
-
Customized-individually-made origin® implants in total knee arthroplasty allow a reliable solution for accurate reproduction of planned implant positioning.J Exp Orthop. 2023 Nov 28;10(1):123. doi: 10.1186/s40634-023-00706-9. J Exp Orthop. 2023. PMID: 38015319 Free PMC article.
-
Comparison of Kinematic Alignment and Mechanical Alignment in Total Knee Arthroplasty: A Meta-analysis of Randomized Controlled Clinical Trials.Orthop Surg. 2020 Dec;12(6):1567-1578. doi: 10.1111/os.12826. Epub 2020 Oct 25. Orthop Surg. 2020. PMID: 33099892 Free PMC article. Review.
-
Differences in Trochlear Morphology of a New Femoral Component Designed for Kinematic Alignment from a Mechanical Alignment Design.Bioengineering (Basel). 2024 Jan 8;11(1):62. doi: 10.3390/bioengineering11010062. Bioengineering (Basel). 2024. PMID: 38247939 Free PMC article.
-
Robotic-assisted surgery and kinematic alignment in total knee arthroplasty (RASKAL study): a protocol of a national registry-nested, multicentre, 2×2 factorial randomised trial assessing clinical, intraoperative, functional, radiographic and survivorship outcomes.BMJ Open. 2022 Jun 10;12(6):e051088. doi: 10.1136/bmjopen-2021-051088. BMJ Open. 2022. PMID: 35688590 Free PMC article.
References
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Research Materials