Usefulness of vessel-sealing devices combined with crush clamping method for hepatectomy: a retrospective cohort study

Affiliations
Free article

Usefulness of vessel-sealing devices combined with crush clamping method for hepatectomy: a retrospective cohort study

Atsushi Nanashima et al. Int J Surg. 2013.
Free article

Abstract

Background: Blood loss during resection of the hepatic parenchyma in hepatectomy can be minimized using vessel-sealing (VS) devices. Some sealing devices were retrospectively compared to evaluate the efficacy of each device for controlling blood loss, transection time and postoperative complications in hepatectomy as a cohort study.

Methods: Between 2005 and September 2012, hepatectomy was underwent in 150 patients using one of three types of LigaSure™ (Dolphin Tip Laparoscopic Instrument, Precise or Small Jaw) or the Harmonic Focus or Ace ultrasonic dissecting sealer. Results were compared to crush-clamping alone as the control method by the historical study (n = 81).

Results: Irrespective of the vessel-sealing device used for underlying chronic hepatitis, blood loss, blood transfusion rate, operating time and transection time were significantly reduced in the VS group compared with controls (p < 0.05). Rates of postoperative bile leakage and intra-abdominal abscess formation were significantly lower in the VS group than in controls (p < 0.05). Comparing devices, LigaSure Small Jaw and Harmonic Focus showed lower blood loss, shorter transection time and reduced rates of post-hepatectomy complications, in turn resulting in shorter hospital stays (p < 0.05). Tendencies toward uncontrolled ascites and bile leakage were only concern with the use of Harmonic Focus. Satisfactory surgical results were achieved using the sealing device for laparoscopic hepatectomy.

Conclusions: The use of energy sealing devices improves surgical results and avoids hepatectomy-related complications. Adequate use of vessel sealers is necessary for safe and rapid completion of hepatic resection.

Keywords: Bloodless: morbidity; Cohort study; Crush clamping; Hepatectomy; Vessel sealing.