Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2013 Apr;7(2):46-51.
doi: 10.4103/0973-6042.114224.

An in-vitro study of rotator cuff tear and repair kinematics using single- and double-row suture anchor fixation

Affiliations

An in-vitro study of rotator cuff tear and repair kinematics using single- and double-row suture anchor fixation

Angela E Kedgley et al. Int J Shoulder Surg. 2013 Apr.

Abstract

Purpose: Double-row suture anchor fixation of the rotator cuff was developed to reduce repair failure rates. The purpose of this study was to determine the effects of simulated rotator cuff tears and subsequent repairs using single- and double-row suture anchor fixation on three-dimensional shoulder kinematics. It was hypothesized that both single- and double-row repairs would be effective in restoring active intact kinematics of the shoulder.

Materials and methods: Sixteen fresh-frozen cadaveric shoulder specimens (eight matched pairs) were tested using a custom loading apparatus designed to simulate unconstrained motion of the shoulder. In each specimen, the rotator cuff was sectioned to create a medium-sized (2 cm) tear. Within each pair, one specimen was randomized to a single-row suture anchor repair, while the contralateral side underwent a double-row suture anchor repair. Joint kinematics were recorded for intact, torn, and repaired scenarios using an electromagnetic tracking device.

Results: Active kinematics confirmed that a medium-sized rotator cuff tear affected glenohumeral kinematics when compared to the intact state. Single- and double-row suture anchor repairs restored the kinematics of the intact specimen.

Conclusions: This study illustrates the effects of medium-sized rotator cuff tears and their repairs on active glenohumeral kinematics. No significant difference (P ≥ 0.10) was found between the kinematics of single- and double-row techniques in medium-sized rotator cuff repairs.

Clinical relevance: Determining the relative effects of single- and double-row suture anchor repairs of the rotator cuff will allow physicians to be better equipped to treat patients with rotator cuff disease.

Keywords: Double-row; glenohumeral joint; rotator cuff; single-row; suture anchor repair.

PubMed Disclaimer

Conflict of interest statement

Conflict of Interest: None declared.

Figures

Figure 1
Figure 1
An overview of the experimental procedure
Figure 2
Figure 2
Change in plane of glenohumeral elevation from the intact state as a function of elevation angle for all states. Mean (±1 SD) for all specimens presented for 30° to 80° of elevation
Figure 3
Figure 3
Change in internal-external rotation angle from the intact state as a function of elevation angle for all states. Mean (±1 SD) for all specimens presented for 30° to 80° of elevation
Figure 4
Figure 4
Change in (a) superior-inferior and (b) anterior-posterior position of the humeral head from the intact state as a function of elevation angle for all states. Mean (±1 SD) for all specimens presented for 30° to 80° of elevation

References

    1. Milgrom C, Schaffler M, Gilbert S, van Holsbeeck M. Rotator-cuff changes in asymptomatic adults. The effect of age, hand dominance and gender. J Bone Joint Surg Br. 1995;77:296–8. - PubMed
    1. Burkhart SS. Fluoroscopic comparison of kinematic patterns in massive rotator cuff tears. A suspension bridge model. Clin Orthop Relat Res. 1992;284:144–52. - PubMed
    1. Kelly BT, Williams RJ, Cordasco FA, Backus SI, Otis JC, Weiland DE, et al. Differential patterns of muscle activation in patients with symptomatic and asymptomatic rotator cuff tears. J Shoulder Elbow Surg. 2005;14:165–71. - PubMed
    1. Mura N, O’Driscoll SW, Zobitz ME, Heers G, Jenkyn TR, Chou SM, et al. The effect of infraspinatus disruption on glenohumeral torque and superior migration of the humeral head: A biomechanical study. J Shoulder Elbow Surg. 2003;12:179–84. - PubMed
    1. Su WR, Budoff JE, Luo ZP. The effect of posterosuperior rotator cuff tears and biceps loading on glenohumeral translation. Arthroscopy. 2010;26:578–86. - PubMed

LinkOut - more resources