A direct liquid chromatographic quantitation of ciprofloxacin in microsamples of plasma with fluorometric detection
- PMID: 2396312
- DOI: 10.1097/00007691-199007000-00014
A direct liquid chromatographic quantitation of ciprofloxacin in microsamples of plasma with fluorometric detection
Abstract
We describe a rapid liquid chromatographic assay for ciprofloxacin in 20-50 microliter samples of plasma by use of C18 cartridge in conjunction with a radial compression system and a C18 precolumn module. The mobile phase consisted of an ammonium phosphate solution (pH 2.5), acetonitrile, and methanol. The sample was diluted with an equal volume of water and directly injected into the cartridge. The drug and internal standard (quinine bisulfate) were detected spectrofluorometrically. The peak height ratio (PHR) varied linearly with concentration (0.05-4 micrograms/ml), and the coefficient of variation of the PHR did not exceed 5%. No interference for any endogenous substance or other concomitantly used drug in the assay was detected. This method is currently being used to monitor ciprofloxacin in patients treated with this drug for brucellosis.
Similar articles
-
Microdetermination of propofol in plasma by a rapid and sensitive liquid chromatographic method.J Pharm Biomed Anal. 1996 Oct;15(1):99-104. doi: 10.1016/0731-7085(96)01818-3. J Pharm Biomed Anal. 1996. PMID: 8895080
-
Liquid chromatographic analysis of mesna and dimesna in plasma and urine of patients treated with mesna.Ther Drug Monit. 1995 Apr;17(2):153-8. doi: 10.1097/00007691-199504000-00009. Ther Drug Monit. 1995. PMID: 7624904
-
Rapid liquid chromatographic analysis of mitoxantrone in plasma with C18 sample purification.J Pharm Biomed Anal. 1989;7(7):877-82. doi: 10.1016/0731-7085(89)80009-3. J Pharm Biomed Anal. 1989. PMID: 2562289
-
Direct, simultaneous measurement of chloramphenicol and its monosuccinate ester in micro-samples of plasma by radial-compression liquid chromatography.Clin Chem. 1987 Oct;33(10):1814-6. Clin Chem. 1987. PMID: 3665035
-
An expedient liquid chromatographic micromeasurement of isoniazid in plasma by use of electrochemical detection.Ther Drug Monit. 1991 May;13(3):254-9. doi: 10.1097/00007691-199105000-00012. Ther Drug Monit. 1991. PMID: 1926281
Cited by
-
Food intake attenuates the drug interaction between new quinolones and aluminum.J Pharm Health Care Sci. 2018 May 14;4:11. doi: 10.1186/s40780-018-0107-1. eCollection 2018. J Pharm Health Care Sci. 2018. PMID: 29785276 Free PMC article.
MeSH terms
Substances
LinkOut - more resources