Effects of physical parameters on high temperature ultrasound hyperthermia
- PMID: 2396329
- DOI: 10.1016/0301-5629(90)90070-s
Effects of physical parameters on high temperature ultrasound hyperthermia
Abstract
The purpose of this research was to investigate the feasibility of inducing perfusion independent, predictable therapeutic thermal dose using high power ultrasonic pulses. Computer simulations were used to study the effects of blood perfusion, tissue properties, transducer characteristics, and treatment geometry on the temperature elevation and thermal dose delivered by short ultrasonic pulses. Experiments were conducted in vitro and in vivo to investigate the effects of blood perfusion changes. Results show that short pulse lengths (less than or equal to 2 s) and small focal diameters (approximately 3 mm) give temperature elevations and thermal doses which are nearly perfusion independent. Normal fluctuations in tissue properties should not have a significant effect on the treatment provided that proper choice of transducer is made for each individual application.
Similar articles
-
The effects of tissue heterogeneities and large blood vessels on the thermal exposure induced by short high-power ultrasound pulses.Int J Hyperthermia. 1992 Jan-Feb;8(1):45-59. doi: 10.3109/02656739209052878. Int J Hyperthermia. 1992. PMID: 1545163
-
Focal spacing and near-field heating during pulsed high temperature ultrasound therapy.Ultrasound Med Biol. 1993;19(9):777-87. doi: 10.1016/0301-5629(93)90094-5. Ultrasound Med Biol. 1993. PMID: 8134978
-
A scanned, focused, multiple transducer ultrasonic system for localized hyperthermia treatments. 1987.Int J Hyperthermia. 2010 Feb;26(1):1-11. doi: 10.3109/02656730903492916. Int J Hyperthermia. 2010. PMID: 20100046
-
A translational review of hyperthermia biology.Int J Hyperthermia. 2025 Dec;42(1):2447952. doi: 10.1080/02656736.2024.2447952. Epub 2025 Jan 12. Int J Hyperthermia. 2025. PMID: 39799944 Review.
-
Analytical modelling of ultrasonically induced tissue heating.Ultrasound Med Biol. 1987 Oct;13(10):607-18. doi: 10.1016/0301-5629(87)90058-5. Ultrasound Med Biol. 1987. PMID: 3318068 Review.
Cited by
-
Dynamic contrast-enhanced MR evaluation of prostate cancer before and after endorectal high-intensity focused ultrasound.Radiol Med. 2013 Aug;118(5):851-62. doi: 10.1007/s11547-012-0876-9. Epub 2012 Sep 17. Radiol Med. 2013. PMID: 22986696
-
The surgical treatment of atrial fibrillation.Heart Rhythm. 2009 Aug;6(8 Suppl):S45-50. doi: 10.1016/j.hrthm.2009.05.019. Epub 2009 May 22. Heart Rhythm. 2009. PMID: 19631907 Free PMC article. Review.
-
Evolution of acoustically vaporized microdroplets in gas embolotherapy.J Biomech Eng. 2012 Mar;134(3):031010. doi: 10.1115/1.4005980. J Biomech Eng. 2012. PMID: 22482690 Free PMC article.
-
Acceleration of ultrasound thermal therapy by patterned acoustic droplet vaporization.J Acoust Soc Am. 2014 Jan;135(1):537-44. doi: 10.1121/1.4828832. J Acoust Soc Am. 2014. PMID: 24437794 Free PMC article.
-
Acoustic droplet vaporization for enhancement of thermal ablation by high intensity focused ultrasound.Acad Radiol. 2011 Sep;18(9):1123-32. doi: 10.1016/j.acra.2011.04.012. Epub 2011 Jun 23. Acad Radiol. 2011. PMID: 21703883 Free PMC article.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Other Literature Sources