Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2013 Aug 21;95(16):e113(1-7).
doi: 10.2106/JBJS.K.00202.

The role of medial comminution and calcar restoration in varus collapse of proximal humeral fractures treated with locking plates

Affiliations

The role of medial comminution and calcar restoration in varus collapse of proximal humeral fractures treated with locking plates

Brent A Ponce et al. J Bone Joint Surg Am. .

Abstract

Background: Proximal humeral fractures that are treated with locked plate constructs remain susceptible to collapse into a varus position. The objectives of the present study were to examine how medial comminution affects fracture stability and to determine the effect of calcar fixation on osteosynthesis stability.

Methods: Eleven matched pairs of cadaveric humeri were osteotomized to create standard three-part fractures involving the surgical neck and the greater tuberosity. Five matched pairs were randomly assigned to have the medial calcar region remain intact. Six matched pairs had removal of a 10-mm medially based wedge of bone to simulate medial comminution. All fractures were stabilized in a uniform fashion with a proximal humeral locking plate. The constructs were secured, and the superior portion of the humeral head was subjected to compressive loading to induce varus collapse. Load-to-failure and energy-to-failure values along with stiffness and displacement at the time of failure were determined.

Results: Medial comminution decreased the mean load to failure by 48% (523 N) (p = 0.015) and the mean energy to failure by 44% (2009 Nmm) (p = 0.013). The use of calcar screw fixation increased the mean load to failure by 31% (219 N) (p = 0.002) and the mean energy to failure by 44% (1279 Nmm) (p = 0.006).

Conclusions: Medial comminution significantly decreased the stability of proximal humeral fracture fixation constructs. Calcar restoration with screw fixation significantly improved the stability of repaired fractures in cadaveric specimens.

Clinical relevance: The data suggest that medial comminution is a predictor of poor stability of proximal humeral fractures and that stability may be improved through calcar restoration.

PubMed Disclaimer

Publication types

LinkOut - more resources