Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2013 Oct;46(4):418-23.
doi: 10.1016/j.ejvs.2013.07.018. Epub 2013 Aug 22.

The benefits of EVAR planning using a 3D workstation

Affiliations
Free article

The benefits of EVAR planning using a 3D workstation

J Sobocinski et al. Eur J Vasc Endovasc Surg. 2013 Oct.
Free article

Abstract

Objectives: To evaluate the influence of planning endovascular aneurysm repair (EVAR) with a three-dimensional (3D) workstation on early and midterm outcomes.

Methods: All patients undergoing infrarenal EVAR performed between 2006 and 2009 at our institution were included in the current study. Prior to 2008 (group 1), endograft sizing was performed by interrogation of computed tomography angiography axial images. After 2008 (group 2), endograft sizing was routinely performed using a 3D workstation (Aquarius, Terarecon), allowing for multiplanar reconstruction and centerline analysis. Pre-, peri-, postoperative, and follow-up data were prospectively entered in an electronic database. All postoperative complications and subsequent secondary interventions depicted during the 2-year period following EVAR were compared. Secondary intervention and mortality rates were defined at 2 years and compared. Freedom from secondary intervention and overall survival rates were calculated using the Kaplan-Meier method during follow-up and compared by log-rank test.

Results: A total of 295 patients (149 patients in group 1 and 146 patients in group 2) were included. All patients had completed a minimum of 2 years of follow-up. During this 2-year period following EVAR, the type 1 endoleak rate was 8.7% in group 1 and 1.4% in group 2 (p = .004) respectively. Secondary intervention rates related to type 1 endoleak was 5.4% in group 1 and 0 in group 2 (p < .001). No difference was observed regarding all-cause mortality, aneurysm-related death, and freedom from secondary intervention rates during follow-up.

Conclusion: The routine use of 3D workstations for EVAR planning significantly reduces the rate of type 1 endoleaks and, therefore, the rate of related secondary interventions.

Keywords: Endograft; Planning; Three-dimensional workstation.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources