. 2013 Jul;2(4):408-18.
doi: 10.3978/j.issn.2225-319X.2013.07.23.

Systematic review of robotic-assisted, totally endoscopic coronary artery bypass grafting

Affiliations

Systematic review of robotic-assisted, totally endoscopic coronary artery bypass grafting

Michael Seco et al. Ann Cardiothorac Surg. 2013 Jul.

Abstract

Background: Advancements in surgical robotic technology over the last two decades have enabled coronary artery bypass grafting to be performed totally endoscopically, and have the potential to significantly change clinical practice in the future.

Methods: A systematic review of studies reporting clinical outcomes of total endoscopic coronary artery bypass grafting (TECABG) was performed.

Results: 14 appraised studies included 880 beating heart TECABGs, 360 arrested heart TECABGs, 633 one-vessel operations and 357 two-vessel operations. Patients were generally low-risk. There was a significant learning curve. The weighted means for short-term beating heart and arrested heart TECABG results respectively were: intraoperative exclusion rate of 5.7% and 1.9%, intraoperative conversion rate of 5.6% and 15.0%, all-cause mortality of 1.2% and 0.4%, stroke of 0.7% and 0.8%, myocardial infarction of 0.8% and 1.8%, new onset atrial fibrillation of 10.7% and 5.1% and post-operative reintervention rate of 2.6% and 2.3%. The overall rate of short term postoperative graft patency for beating heart and arrested heart TECABG was 98.3% and 96.4% respectively.

Conclusions: Appropriate patient selection was important in minimizing the risk of intraoperative and postoperative complications. Short-term outcomes of both beating and arrested heart TECABG were acceptable, but results so far have been heterogeneous. There were fewer studies reporting intermediate to long-term outcomes, but results were encouraging, and further investigation and development of the procedure is warranted.

Keywords: Coronary artery bypass; endoscopy; off-pump; robotics.

PubMed Disclaimer

Figures

Figure 1
Figure 1
Search strategy of the systematic review on totally endoscopic coronary artery bypass grafting

References

    1. Cao C, Manganas C, Bannon PG, et al. Drug-eluting stents versus coronary artery bypass graft surgery in left main coronary artery disease: a meta-analysis of early outcomes from randomized and nonrandomized studies. J Thorac Cardiovasc Surg 2013;145:738-47 - PubMed
    1. Puskas JD, Thourani VH, Kilgo P, et al. Off-pump coronary artery bypass disproportionately benefits high-risk patients. Ann Thorac Surg 2009;88:1142-7 - PubMed
    1. Edelman JJ, Yan TD, Padang R, et al. Off-pump coronary artery bypass surgery versus percutaneous coronary intervention: a meta-analysis of randomized and nonrandomized studies. Ann Thorac Surg 2010;90:1384-90 - PubMed
    1. Bonaros N, Schachner T, Wiedemann D, et al. Quality of life improvement after robotically assisted coronary artery bypass grafting. Cardiology 2009;114:59-66 - PubMed
    1. Bonatti J, Schachner T, Bernecker O, et al. Robotic totally endoscopic coronary artery bypass: program development and learning curve issues. J Thorac Cardiovasc Surg 2004;127:504-10 - PubMed