Safety and efficacy of a totally subcutaneous implantable-cardioverter defibrillator
- PMID: 23979626
- DOI: 10.1161/CIRCULATIONAHA.113.003042
Safety and efficacy of a totally subcutaneous implantable-cardioverter defibrillator
Abstract
Background: The most frequent complications associated with implantable cardioverter-defibrillators (ICDs) involve the transvenous leads. A subcutaneous implantable cardioverter-defibrillator (S-ICD) has been developed as an alternative system. This study evaluated the safety and effectiveness of the S-ICD System (Cameron Health/Boston Scientific) for the treatment of life-threatening ventricular arrhythmias (ventricular tachycardia/ventricular fibrillation).
Methods and results: This prospective, nonrandomized, multicenter trial included adult patients with a standard indication for an ICD, who neither required pacing nor had documented pace-terminable ventricular tachycardia. The primary safety end point was the 180-day S-ICD System complication-free rate compared with a prespecified performance goal of 79%. The primary effectiveness end point was the induced ventricular fibrillation conversion rate compared with a prespecified performance goal of 88%, with success defined as 2 consecutive ventricular fibrillation conversions of 4 attempts. Detection and conversion of spontaneous episodes were also evaluated. Device implantation was attempted in 321 of 330 enrolled patients, and 314 patients underwent successful implantation. The cohort was followed for a mean duration of 11 months. The study population was 74% male with a mean age of 52±16 years and mean left ventricular ejection fraction of 36±16%. A previous transvenous ICD had been implanted in 13%. Both primary end points were met: The 180-day system complication-free rate was 99%, and sensitivity analysis of the acute ventricular fibrillation conversion rate was >90% in the entire cohort. There were 38 discrete spontaneous episodes of ventricular tachycardia/ventricular fibrillation recorded in 21 patients (6.7%), all of which successfully converted. Forty-one patients (13.1%) received an inappropriate shock.
Conclusions: The findings support the efficacy and safety of the S-ICD System for the treatment of life-threatening ventricular arrhythmias.
Trial registration: ClinicalTrials.gov NCT01064076.
Keywords: defibrillators, implantable; heart arrest; tachycardia.
Comment in
-
The subcutaneous implantable defibrillator: a new technology that raises an existential question for the implantable cardioverter-defibrillator.Circulation. 2013 Aug 27;128(9):938-40. doi: 10.1161/CIRCULATIONAHA.113.004794. Circulation. 2013. PMID: 23979625 No abstract available.
Publication types
MeSH terms
Associated data
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Miscellaneous
