[Comparison of Pentax-AWS, GlideScope Cobalt, and Macintosh laryngoscope in patients for nasotracheal intubation]
- PMID: 23984572
[Comparison of Pentax-AWS, GlideScope Cobalt, and Macintosh laryngoscope in patients for nasotracheal intubation]
Abstract
Background: We compared the time for instrumentation in nasotracheal intubation using Pentax-AWS and Glidescope to that using the Macintosh laryngoscope in patients with normal airway.
Methods: After local ethics board approval, 60 patients requiring dental or oral surgery were allocated randomly to Pentax-AWS, Glidescope and Macintosh groups. One experienced anesthesiologist performed nasotracheal intubation in all patients.
Results: The times for instrumentation using Pentax-AWS and Glidescope, and Macintosh laryngoscope were 37 +/- 12s, 33 +/- 9s, and 30 +/- 12s, respectively. There were no differences among the three devices.
Cconclusions: When operated by experienced anesthesiologists, both Pentax-AWS and Glidescope showed similar performance for nasotracheal intubation compared with Macintosh laryngoscope in normal airway patients.