Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2013 Dec;191(6):611-7.
doi: 10.1007/s00408-013-9502-4. Epub 2013 Aug 30.

The cryo-needle: a new tool for histological biopsies. A feasibility study

Affiliations

The cryo-needle: a new tool for histological biopsies. A feasibility study

Karl-Josef Franke et al. Lung. 2013 Dec.

Abstract

Purpose: Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a standard procedure for intrathoracic lymph node biopsies. The newly developed cryo-needle operates in a similar way to the EBUS-TBNA but is able to obtain specimens for histological evaluation. The purpose of this animal study was to evaluate the feasibility, effect, and safety of the cryo-needle biopsies.

Methods: Four EBUS-guided cryo-needle biopsies were obtained from a mediastinal lymph node of a healthy pig. In an open surgery approach, cryo-needle biopsies using activation times of 1, 2, and 3 s (A1/A2/A3) and needle biopsies using a 21-gauge EBUS-TBNA needle were obtained from mesenteric lymph nodes. Cryo-needle biopsies A2 were performed with (A2+) and without (A2-) an oversheath. The size, weight, percentage of lymphatic tissue and artefact-free area of each cryobiopsy were evaluated. Smears were made with the TBNA-needle aspirates to determine the number of lymphocytes per high-power field (HPF). The bleeding duration was measured.

Results: We successfully obtained EBUS-guided cryo-needle biopsies. The area and weight of the biopsies A3 and A2+ were significantly larger compared with A1 (1.7 ± 0.8 and 1.4 ± 0.3 vs. 0.9 ± 0.4 mm(2); 5.2 ± 2.4 and 3.4 ± 1.8 vs. 1.5 ± 0.7 mg). The percentage of lymphatic tissue of the cryobiopsies was 90 ± 25 and 98 % of samples were artefact-free. The number of lymphocytes/HPF of TBNA-needle smears was 128 ± 54.3. There was no difference in bleeding duration between the techniques.

Conclusions: The cryo-needle yields large histological specimens of high quality.

PubMed Disclaimer

References

    1. Chest. 2007 Aug;132(2):597-602 - PubMed
    1. J Thorac Cardiovasc Surg. 2012 Jun;143(6):1324-9 - PubMed
    1. Chest. 2007 Oct;132(4):1298-304 - PubMed
    1. Respir Care. 2012 Mar;57(3):384-91 - PubMed
    1. Pneumologie. 2010 Jun;64(6):387-9 - PubMed

Publication types

LinkOut - more resources