The correlation between rat retinal nerve fiber layer thickness around optic disc by using optical coherence tomography and histological measurements
- PMID: 23991370
- PMCID: PMC3755295
- DOI: 10.3980/j.issn.2222-3959.2013.04.01
The correlation between rat retinal nerve fiber layer thickness around optic disc by using optical coherence tomography and histological measurements
Abstract
Aim: To explore the correlation between the retinal nerve fiber layer (RNFL) thickness by using optical coherence tomography (OCT) and by histological measurements in normal adult rats and optic nerve transected rats.
Methods: The RNFL thickness of 36 rats was scanned in a circle 3.46mm far from the optic disc by OCT. The two experimental groups were the normal group (n=20 rats) and the optic nerve transected group (n=16 rats). The latter group included 4 groups (n=4/group) surviving for 1 day, 3, 5 and 7 days. Then the RNFL thickness of the same retina area was also measured by NF-200 immunohistochemical staining method. Linear regression was used to analyze the correlation between the data obtained from these two methods.
Results: The RNFL thickness of normal right eyes around optic disc by OCT was 72.35±5.71µm and that of the left eyes was 72.65±5.88µm (P=0.074). The RNFL thickness of the corresponding histological section by immunohistochemistry was 37.54±4.05µm (right eyes) and 37.38±4.23µm (left eyes) (P=0.059). There was a good correlation between the RNFL thickness measured by OCT and that measured by histology (R(2)=0.8131). After optic nerve transection, the trend of the RNFL thickness was thinner with the prolonged survival time. The correlation of the thickness detected by the above two methods was approximately (R(2)=0.8265). Value of the RNFL thickness in rats around optic disc measured by OCT was obviously higher than that measured by common histological measurement in normal adult rats and optic nerve transected rats.
Conclusion: The RNFL thickness measured by OCT has a strong correlation with that measured by histological method. Through OCT scanning, we found that the thickness of RNFL gradually becomes thinner in a time-dependent manner.
Keywords: immunohistochemistry staining; optic nerve transection; optical coherence tomography; rat; relevance analysis; retinal nerve fiber layer thickness.
Figures
References
-
- Huang L, Schuman J, Wang N. Comparison of nerve fiber layer thickness between optical coherence tomography and histomorphometry in glaucomatous monkey eyes. Zhonghua Yan Ke Za Zhi. 2001;37(3):188–192. - PubMed
-
- Schuman JS, Pedut-Kloizman T, Pakter H, Wang N, Guedes V, Huang L, Pieroth L, Scott W, Hee MR, Fujimoto JG, Ishikawa H, Bilonick RA, Kagemann L, Wollstein G. Optical coherence tomography and histologic measurements of nerve fiber layer thickness in normal and glaucomatous monkey eyes. Invest Ophthalmol Vis Sci. 2007;48(8):3645–3654. - PMC - PubMed
-
- Fox J, Marsack J, Kim J, Thomsen S, Rylander HG, Milner TE. Measuring primate RNFL thickness with OCT. IEEE journal of selected topics in quantum electronics. 2001;7(6):899–905.
-
- Luo RJ, Ge J, Guo Y, Zhuo YH. Correlation of retinal thickness measured by optical coherence tomography and histologic studies in rabbits. Chinese Journal of Ocular Fundus Diseases. 2000;16(2):111–113.
-
- Huang LN, Fan N, Cheng HB, Lai MY, Zhao J. Comparability of sensory retinal thickness measured by different OCTs to histological studies in rabbit eyes. Ophthalmology in China. 2009;18(4):239–242.
LinkOut - more resources
Full Text Sources