Learning curve of acetabular cup positioning in total hip arthroplasty using a cumulative summation test for learning curve (LC-CUSUM)
- PMID: 23998991
- DOI: 10.1016/j.arth.2013.07.023
Learning curve of acetabular cup positioning in total hip arthroplasty using a cumulative summation test for learning curve (LC-CUSUM)
Abstract
Despite advances in surgical techniques and instrumentation, optimal cup positioning in total hip arthroplasty (THA) is challenging with a limited accuracy. We evaluated whether a learning curve exists for the optimal cup positioning, using the LC-CUSUM test (Learning curve cumulative summation test). We evaluated the first 100 consecutive THA performed by two surgeons, who had a year of fellowship training in the same teaching hospital. A learning curve of cup positioning was plotted in each series using the LC-CUSUM score. There was no significant difference of numbers of outlier between two surgeons (P = 0.079). Both surgeons completed the learning curve of optimal cup positioning before 50 procedures, and maintained competence. A substantial learning period is necessary in the optimal positioning of an acetabular cup.
Keywords: LC-CUSUM test; cup position; hip; learning curve; total hip arthroplasty.
© 2014.
Comment in
-
Patient injuries in primary total hip replacement.Acta Orthop. 2016 Jun;87(3):209-17. doi: 10.3109/17453674.2015.1135662. Epub 2016 Jan 25. Acta Orthop. 2016. PMID: 26808350 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical