Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2013 Oct;54(5):647-52.

Patency of the saphenous vein conduit anastomosed to the aortic dacron graft

Affiliations
  • PMID: 24002395

Patency of the saphenous vein conduit anastomosed to the aortic dacron graft

I Kara et al. J Cardiovasc Surg (Torino). 2013 Oct.

Abstract

Aim: The medium term patency rate of proximal saphenous vein conduit anastomosed onto the aortic dacron graft in patients was investigated.

Methods: Forty-eight patients who underwent aortic graft replacement and coronary artery bypass grafting (CABG) in our clinic between February 2004 and December 2011 were included in the study. The study was designed as two phases. In the first phase, records of the patients who have undergone ascending aorta replacement with concomitant CABG were scanned retrospectively. In the second phase, saphenous vein graft patency was assessed in living patients with multislice computerized tomography (CT) by cross-sectional prospective study.

Results: A total of 61 saphenous vein grafts (SVG) were used in patients who have undergone concomitant CABG. A total of 39.6% of the patients had single vessel disease, 45.8% of the patients had two-vessel disease and 14.6% three-vessel or more disease. The mean follow-up duration was 3.7±1.9 years. SVG cumulative patency rate was 45.9%. Although the coronary artery position in which the saphenous graft was least occluded was the left anterior descending artery (9.1%) and the position in which it was most occluded was right coronary artery (51.5%), there was no statistically significant difference among the coronary positions in which the SVG was used (p>0.05).

Conclusion: The saphenous vein conduit anastomosed to the aortic dacron graft may have negative effects on graft patency. The placement of saphenous vein on a native tissue like the innominate artery may have beneficial effects of graft patency by slowing down neointimal hyperplasia.

PubMed Disclaimer

Similar articles

Cited by

MeSH terms

Substances

LinkOut - more resources