Improving laboratory data entry quality using Six Sigma
Abstract
Purpose: The Uganda Makerere University provides clinical laboratory support to over 70 clients in Uganda. With increased volume, manual data entry errors have steadily increased, prompting laboratory managers to employ the Six Sigma method to evaluate and reduce their problems. The purpose of this paper is to describe how laboratory data entry quality was improved by using Six Sigma.
Design/methodology/approach: The Six Sigma Quality Improvement (QI) project team followed a sequence of steps, starting with defining project goals, measuring data entry errors to assess current performance, analyzing data and determining data-entry error root causes. Finally the team implemented changes and control measures to address the root causes and to maintain improvements. Establishing the Six Sigma project required considerable resources and maintaining the gains requires additional personnel time and dedicated resources.
Findings: After initiating the Six Sigma project, there was a 60.5 percent reduction in data entry errors from 423 errors a month (i.e. 4.34 Six Sigma) in the first month, down to an average 166 errors/month (i.e. 4.65 Six Sigma) over 12 months. The team estimated the average cost of identifying and fixing a data entry error to be $16.25 per error. Thus, reducing errors by an average of 257 errors per month over one year has saved the laboratory an estimated $50,115 a year.
Practical implications: The Six Sigma QI project provides a replicable framework for Ugandan laboratory staff and other resource-limited organizations to promote quality environment. Laboratory staff can deliver excellent care at a lower cost, by applying QI principles.
Originality/value: This innovative QI method of reducing data entry errors in medical laboratories may improve the clinical workflow processes and make cost savings across the health care continuum.
Similar articles
-
Six Sigma: not for the faint of heart.Radiol Manage. 2003 Mar-Apr;25(2):40-53. Radiol Manage. 2003. PMID: 12800564
-
Linking Six Sigma to simulation: a new roadmap to improve the quality of patient care.Int J Health Care Qual Assur. 2012;25(4):254-73. doi: 10.1108/09526861211221473. Int J Health Care Qual Assur. 2012. PMID: 22755480
-
Application of Six Sigma methodology to a diagnostic imaging process.Int J Health Care Qual Assur. 2012;25(4):274-90. doi: 10.1108/09526861211221482. Int J Health Care Qual Assur. 2012. PMID: 22755481
-
Can Lean Six Sigma be used to reduce medication errors in the health-care sector?Leadersh Health Serv (Bradf Engl). 2018 Oct 1;31(4):426-433. doi: 10.1108/LHS-09-2017-0055. Epub 2018 Jan 30. Leadersh Health Serv (Bradf Engl). 2018. PMID: 30234447 Review.
-
Six Sigma in healthcare delivery.Int J Health Care Qual Assur. 2013;26(7):601-26. doi: 10.1108/IJHCQA-09-2011-0054. Int J Health Care Qual Assur. 2013. PMID: 24167920 Review.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources