Biometrical analysis of the shoulder joint regarding glenoid implant dimensions for arthroplasty
- PMID: 24005377
- DOI: 10.1007/s00276-013-1197-y
Biometrical analysis of the shoulder joint regarding glenoid implant dimensions for arthroplasty
Abstract
Purpose: Reduced bone stock and difficult intraoperative orientation are challenges in glenoid replacement surgery. New implant designs and methods for fixation, such as locking screws, extra-long central pegs and/or central compression screws are targeting these issues. The objective of this study is the analysis of the glenoid dimension regarding maximum central peg diameter and peg length (PL), and maximum screw length (SL) for glenoid fixation.
Methods: Retrospective analysis of magnetic resonance imaging (n = 50) scans. Measurement of the maximum inferior glenoid diameter (GD), SL, maximum length of a 9.9, 10 and 11.4 mm central peg (PL) in the transverse plane; glenoid version (GV), humeral head diameter (HHD). Two independent measurements.
Results: Mean age: 49.0 ± 15.7 years (17-80) (n = 20 female, 49.6 ± 16.0; n = 30 male, 48.6 ± 15.7). Mean values of measurement were GD: 28.9 ± 3.7 mm (21-39); SL: 34.1 ± 4.9 mm (26-44); PL 9.9 mm: 19.4 ± 4.3 mm (9-30); PL 10 mm: 19.0 ± 4.4 mm (8-30); PL 11.4 mm: 16.5 ± 4.1 mm (7-26) with significant gender differences (p = 0.001; p = 0.022; p = 0.001); GV: -0.6° ± 4.9° (-10 to 11); HHD: 50.0 mm ± 4.9 (41-61). There was good correlation between PL and SL (r = 0.32, p = 0.024) and for GD and PL (r = 0.61, p = 0.001; r = 0.57, p = 0.001; r = 0.96, p = 0.001). The ratio of HHD and GD was very constant with 0.6 ± 0.07.
Conclusions: These data indicate the high interindividual variability of glenoid morphology including significant gender-related differences. The good correlation between humeral head size and GD and maximum central PL can be helpful for cases with reduced bone stock in decision-making about implant size and bone grafting.
Similar articles
-
Glenoid bone grafting in reverse shoulder arthroplasty for long-standing anterior shoulder dislocation.J Shoulder Elbow Surg. 2014 Nov;23(11):1655-61. doi: 10.1016/j.jse.2014.02.017. Epub 2014 May 14. J Shoulder Elbow Surg. 2014. PMID: 24835299
-
Influence of different peg length in glenoid bone loss: A biomechanical analysis regarding primary stability of the glenoid baseplate in reverse shoulder arthroplasty.Technol Health Care. 2015;23(6):855-69. doi: 10.3233/THC-151031. Technol Health Care. 2015. PMID: 26409518
-
The effect of screw position on the initial fixation of a reverse total shoulder prosthesis in a glenoid with a cavitary bone defect.J Shoulder Elbow Surg. 2008 May-Jun;17(3):479-86. doi: 10.1016/j.jse.2007.09.002. Epub 2008 Feb 20. J Shoulder Elbow Surg. 2008. PMID: 18282725
-
[Glenoid reconstruction in revision shoulder arthroplasty].Oper Orthop Traumatol. 2019 Apr;31(2):98-114. doi: 10.1007/s00064-019-0594-8. Epub 2019 Mar 15. Oper Orthop Traumatol. 2019. PMID: 30874867 Review. German.
-
[Current status and perspectives of shoulder replacement].Unfallchirurg. 1999 Sep;102(9):668-83. doi: 10.1007/s001130050465. Unfallchirurg. 1999. PMID: 10506358 Review. German.
Cited by
-
Age-dependent variation of glenohumeral anatomy: a radiological study.Int Orthop. 2016 Jan;40(1):87-93. doi: 10.1007/s00264-015-2863-y. Epub 2015 Jul 7. Int Orthop. 2016. PMID: 26150334
-
Radiologic assessment of glenohumeral relationship: reliability and reproducibility of lateral humeral offset.Surg Radiol Anat. 2015 May;37(4):363-8. doi: 10.1007/s00276-015-1424-9. Epub 2015 Jan 15. Surg Radiol Anat. 2015. PMID: 25588981
References
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical