Monitoring volume and fluid responsiveness: from static to dynamic indicators
Abstract
Fluid therapy represents, most of the time, the first-line treatment of circulatory failure in critically ill patients. However, after initial resuscitation, fluid administration can be deleterious in patients with sepsis and/or acute respiratory distress syndrome. In this context, several tests have been developed to predict fluid responsiveness and fluid unresponsiveness to identify patients who can be eligible for fluid therapy (fluid respondents) and those who cannot benefit from volume expansion (fluid non-respondents) and in whom fluid loading can even be deleterious. For this purpose, 'static' markers of cardiac preload have been used for many years. However, a large number of studies clearly showed that neither pressure nor volume markers of cardiac preload could predict fluid responsiveness. This is the reason why a 'dynamic approach' has been developed to assess preload responsiveness. The respiratory variation of arterial pulse pressure and of other surrogates of stroke volume has been used first for this purpose and has received a large amount of evidence. However, such indices suffer from several limitations. In such instances, alternative methods such as passive leg raising, end-expiratory occlusion test or 'mini' fluid challenge have been developed.
Keywords: end-expiratory occlusion test; fluid challenge; fluid responsiveness; fluid therapy; passive leg raising; pulse pressure variation.
Copyright © 2013 Elsevier Ltd. All rights reserved.
Similar articles
-
Passive leg-raising and end-expiratory occlusion tests perform better than pulse pressure variation in patients with low respiratory system compliance.Crit Care Med. 2012 Jan;40(1):152-7. doi: 10.1097/CCM.0b013e31822f08d7. Crit Care Med. 2012. PMID: 21926581
-
Passive leg raising is predictive of fluid responsiveness in spontaneously breathing patients with severe sepsis or acute pancreatitis.Crit Care Med. 2010 Mar;38(3):819-25. doi: 10.1097/CCM.0b013e3181c8fe7a. Crit Care Med. 2010. PMID: 20016380
-
Prediction of fluid responsiveness in acute respiratory distress syndrome patients ventilated with low tidal volume and high positive end-expiratory pressure.Crit Care Med. 2008 Oct;36(10):2810-6. doi: 10.1097/CCM.0b013e318186b74e. Crit Care Med. 2008. PMID: 18766099
-
Pulse pressure variation and ARDS.Minerva Anestesiol. 2013 Apr;79(4):398-407. Epub 2013 Jan 31. Minerva Anestesiol. 2013. PMID: 23370121 Review.
-
Fluid bolus therapy: monitoring and predicting fluid responsiveness.Curr Opin Crit Care. 2015 Oct;21(5):388-94. doi: 10.1097/MCC.0000000000000240. Curr Opin Crit Care. 2015. PMID: 26348418 Review.
Cited by
-
Assessing the Utility of End-Tidal Carbon Dioxide as a Marker for Fluid Responsiveness in Cardiogenic Shock.Cureus. 2021 Feb 5;13(2):e13164. doi: 10.7759/cureus.13164. Cureus. 2021. PMID: 33692926 Free PMC article.
-
Update on the assessment of fluid responsiveness.J Anesth. 2020 Apr;34(2):163-166. doi: 10.1007/s00540-019-02731-4. Epub 2020 Jan 7. J Anesth. 2020. PMID: 31912310 No abstract available.
-
Comparative evaluation of stroke volume variation measured by pulse wave transit time and arterial pressure wave.Technol Health Care. 2024;32(2):651-662. doi: 10.3233/THC-220849. Technol Health Care. 2024. PMID: 37483029 Free PMC article.
-
Suspected infection in afebrile patients: Are they septic?Medicine (Baltimore). 2017 Mar;96(10):e6299. doi: 10.1097/MD.0000000000006299. Medicine (Baltimore). 2017. PMID: 28272257 Free PMC article.
-
Respiratory variations in the photoplethysmographic waveform amplitude depend on type of pulse oximetry device.J Clin Monit Comput. 2016 Jun;30(3):317-25. doi: 10.1007/s10877-015-9720-9. Epub 2015 Jun 12. J Clin Monit Comput. 2016. PMID: 26067403
Publication types
MeSH terms
LinkOut - more resources
Other Literature Sources
Medical