Endoscopic stenting for benign upper gastrointestinal strictures and leaks
- PMID: 24013467
- DOI: 10.1007/s00464-013-3150-x
Endoscopic stenting for benign upper gastrointestinal strictures and leaks
Abstract
Background: Self-expandable metal stents (SEMS) and self-expandable plastic stents (SEPS) maybe used for the treatment of benign upper gastrointestinal (GI) leaks and strictures. This study reviewed our experience with stent insertions in patients with benign upper GI conditions.
Methods: Patients who underwent stent placement for benign upper GI strictures and leaks between March 2007 and April 2011 at a tertiary referral academic center were studied using an endoscopic database and electronic patient records. The technical success, complications, and clinical improvement after stent removal were compared according to type of stent. The outcomes measured were clinical response, adverse events, and predictors of stent migration.
Results: Thirty-eight patients (50 % male, mean age = 54 years, range = 12-82) underwent 121 endoscopic procedures. Twenty patients had stents placed for strictures, and 18 had stents placed for leaks. Stent placement was technically successful in all patients. The average duration of stent placement was 54 days (range = 18-118). Clinical improvement immediately after stent placement was seen in 29 of the 38 patients (76.3 %). Immediate post-procedure adverse events occurred in 8 patients. Late adverse events were seen in 18 patients. Evidence of stent migration occurred in 16 patients and was seen in 42 of the 118 successfully placed stents (35.5 %). Migration was more frequent with fully covered SEMS (p = 0.002). After stent removal, 27 patients were evaluable for long-term success (median follow-up time of 283 days, IQR 38-762). Resolution of strictures or leaks was seen in 11 patients (40.7 %). Predictors for long-term success included increasing age and if the stent did not cross the GE junction.
Conclusions: Placement of SEPS and SEMS for benign refractory strictures and fistulas has modest long-term clinical efficacy and is limited by a significant migration rate. Stent migration is common and frequent with fully covered SEMS compared to other types of stents, regardless of indication or location.
Similar articles
-
Self-expandable metal stents for the treatment of benign upper GI leaks and perforations.Gastrointest Endosc. 2011 May;73(5):890-9. doi: 10.1016/j.gie.2010.12.019. Gastrointest Endosc. 2011. PMID: 21521563
-
Fully covered self-expandable metal stents (SEMS), partially covered SEMS and self-expandable plastic stents for the treatment of benign esophageal ruptures and anastomotic leaks.BMC Gastroenterol. 2012 Feb 29;12:19. doi: 10.1186/1471-230X-12-19. BMC Gastroenterol. 2012. PMID: 22375711 Free PMC article.
-
The role of endoscopic stents in the management of chronic anastomotic and staple line leaks and chronic strictures after bariatric surgery.Surg Obes Relat Dis. 2014 Jul-Aug;10(4):613-7. doi: 10.1016/j.soard.2013.12.018. Epub 2014 Jan 11. Surg Obes Relat Dis. 2014. PMID: 24680763
-
Role of fully covered self-expandable metal stent for treatment of benign biliary strictures and bile leaks.Korean J Radiol. 2012 Jan-Feb;13 Suppl 1(Suppl 1):S67-73. doi: 10.3348/kjr.2012.13.S1.S67. Epub 2012 Apr 23. Korean J Radiol. 2012. PMID: 22563290 Free PMC article. Review.
-
Treating sleeve gastrectomy leak with endoscopic stenting: the Kuwaiti experience and review of recent literature.Surg Endosc. 2014 Dec;28(12):3425-8. doi: 10.1007/s00464-014-3616-5. Epub 2014 Jun 20. Surg Endosc. 2014. PMID: 24946741 Review.
Cited by
-
Safety and Efficacy of Endoscopically Secured Fully Covered Self-Expandable Metallic Stents (FCSEMS) for Post-Bariatric Complex Stenosis.Obes Surg. 2019 Nov;29(11):3484-3492. doi: 10.1007/s11695-019-04021-0. Obes Surg. 2019. PMID: 31254212
-
A Specifically Designed Stent for Anastomotic Leaks after Bariatric Surgery: Experiences in a Tertiary Referral Hospital.Obes Surg. 2016 Aug;26(8):1875-80. doi: 10.1007/s11695-015-2027-6. Obes Surg. 2016. PMID: 26699374
-
Silane surface modification for improved bioadhesion of esophageal stents.Appl Surf Sci. 2014 Aug 30;311:684-689. doi: 10.1016/j.apsusc.2014.05.136. Appl Surf Sci. 2014. PMID: 25663731 Free PMC article.
-
Temporary self-expandable metallic stent placement in post-gastrectomy complications.Gastric Cancer. 2019 Jan;22(1):231-236. doi: 10.1007/s10120-018-0837-7. Epub 2018 May 14. Gastric Cancer. 2019. PMID: 29761324
-
Clinical outcomes of self-expandable stent placement for benign esophageal diseases: A pooled analysis of the literature.World J Gastrointest Endosc. 2015 Feb 16;7(2):135-53. doi: 10.4253/wjge.v7.i2.135. World J Gastrointest Endosc. 2015. PMID: 25685270 Free PMC article.
References
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Miscellaneous