Anterior segment study with the Pentacam Scheimpflug camera in refractive surgery candidates

Affiliations

Anterior segment study with the Pentacam Scheimpflug camera in refractive surgery candidates

Masih Hashemi et al. Middle East Afr J Ophthalmol. 2013 Jul-Sep.

Abstract

Purpose: The purpose of this study was to evaluate the anterior segment measurements according to refractive status in a sample of the Iranian population.

Setting: Rassoul Akram Hospital, Tehran University of Medical Sciences.

Material and methods: IN THIS STUDY, REFRACTIVE SURGERY CANDIDATES WERE ASSIGNED ACCORDING TO THE REFRACTIVE ERROR TO ONE OF THREE GROUPS : emmetropia, myopia, and hyperopia. Myopic eyes were further divided to four subgroups : simple myopic group, simple myopic astigmatism group, high myopic group, and high myopia with astigmatism group. Anterior segment measurements with the Pentacam Scheimpflug system were performed in the right eye of all subjects.

Results: The study sample was comprised of 283 subjects with a mean age of 29.1 ± 7.5 (standard deviation) years. Mean keratometry reading, Anterior chamber depth (ACD) and volume measurements were significantly higher in the myopic group and mean keratometry reading and anterior chamber angle measurements were significantly lower in the hyperopic group (P < 0.05, all comparisons). Maximum anterior elevation (AEmax) and maximum posterior elevation (PEmax), Q value, progression index, minimum corneal thickness, and corneal volume measurements were similar for all groups (P > 0.05, all comparisons). In the myopic subgroups, AEmax and PEmax and maximum keratometry (Kmax) were significantly higher, and ACD was lower in the astigmatic groups (P < 0.05, all comparisons). The Q value was less negative in low myopia (P < 0.05).

Conclusions: Myopic eyes had steeper corneas than hyperopic eyes and anterior chamber measurements were significantly higher in the myopic eyes. In myopic eyes, AEmax and PEmax and Kmax measurements were higher, and ACD measurements were lower in the astigmatic groups.

Keywords: Anterior Chamber; Keratometry; Pachymetry; Pentacam Scheimpflug Camera.

PubMed Disclaimer

Conflict of interest statement

Conflict of Interest: None declared.

Figures

Figure 1
Figure 1
A significant correlation was found between the maximum anterior elevation and corneal astigmatic measurements

References

    1. Piñero DP, Saenz González C, Alió JL. Intraobserver and interobserver repeatability of curvature and aberrometric measurements of the posterior corneal surface in normal eyes using Scheimpflug photography. J Cataract Refract Surg. 2009;35:113–20. - PubMed
    1. Chen D, Lam AK. Intrasession and intersession repeatability of the Pentacam system on posterior corneal assessment in the normal human eye. J Cataract Refract Surg. 2007;33:448–54. - PubMed
    1. Shankar H, Taranath D, Santhirathelagan CT, Pesudovs K. Anterior segment biometry with the Pentacam: Comprehensive assessment of repeatability of automated measurements. J Cataract Refract Surg. 2008;34:103–13. - PubMed
    1. Chen D, Lam AK. Reliability and repeatability of the Pentacam on corneal curvatures. Clin Exp Optom. 2009;92:110–8. - PubMed
    1. Ambrósio R, Jr, Alonso RS, Luz A, Coca Velarde LG. Corneal-thickness spatial profile and corneal-volume distribution: Tomographic indices to detect keratoconus. J Cataract Refract Surg. 2006;32:1851–9. - PubMed