Glove punctures in an orthopaedic trauma unit
- PMID: 2401551
- DOI: 10.1016/0020-1383(90)90090-h
Glove punctures in an orthopaedic trauma unit
Abstract
A series of 421 operations in an orthopaedic trauma unit have been studied for glove punctures; 37.5 per cent of operations had a puncture demonstrated in the surgeon's gloves. The procedures at a high risk of glove punctures were hip operations (57 per cent) and internal fixation (54 per cent). The use of double gloving reduced the contamination of the surgeon's hand in these operation groups to 17 per cent (P less than 0.05). The potential risk of the surgeon being infected by his patients has become increasingly important with the increase in the number of people infected with HIV. The trauma surgeon is at a high risk due to frequent spillage of body fluids in trauma and the difficulty in identifying patients who may be at risk. Reducing the risk to the surgeon is difficult but awareness of the areas of potential contamination such as glove puncture may help.
Similar articles
-
Outer gloves in orthopaedic procedures. Cloth compared with latex.J Bone Joint Surg Am. 1990 Jul;72(6):914-7. J Bone Joint Surg Am. 1990. PMID: 2195035 Clinical Trial.
-
Glove punctures in orthopaedic surgery.Int Orthop. 2004 Feb;28(1):36-9. doi: 10.1007/s00264-003-0510-5. Epub 2003 Oct 8. Int Orthop. 2004. PMID: 14534831 Free PMC article.
-
Surgeon protection: early recognition of glove perforation using a green under glove.J R Coll Surg Edinb. 1996 Dec;41(6):395-6. J R Coll Surg Edinb. 1996. PMID: 8997027
-
[Surgical gloves--how well do the protect against infections?].Gesundheitswesen. 1999 Aug-Sep;61(8-9):398-403. Gesundheitswesen. 1999. PMID: 10535220 Review. German.
-
Choosing the right surgical glove: an overview and update.Br J Nurs. 2008 Jun 26-Jul 9;17(12):740-4. doi: 10.12968/bjon.2008.17.12.30292. Br J Nurs. 2008. PMID: 18825848 Review.
Cited by
-
High Risk of Surgical Glove Perforation From Surgical Rotatory Instruments.Clin Orthop Relat Res. 2016 Nov;474(11):2513-2517. doi: 10.1007/s11999-016-4948-3. Epub 2016 Jun 23. Clin Orthop Relat Res. 2016. PMID: 27339122 Free PMC article.
-
Double gloving to reduce surgical cross-infection.Cochrane Database Syst Rev. 2006 Jul 19;2006(3):CD003087. doi: 10.1002/14651858.CD003087.pub2. Cochrane Database Syst Rev. 2006. PMID: 16855997 Free PMC article.
-
Rate of surface contamination in the operating suite during revision total joint arthroplasty.Arthroplast Today. 2018 Oct 29;5(1):96-99. doi: 10.1016/j.artd.2018.09.007. eCollection 2019 Mar. Arthroplast Today. 2018. PMID: 31020031 Free PMC article.
-
Occult glove perforation during ophthalmic surgery.Trans Am Ophthalmol Soc. 1992;90:71-91; discussion 92-5. Trans Am Ophthalmol Soc. 1992. PMID: 1494836 Free PMC article.
-
Hazards to surgeons in trauma and elective orthopaedic surgery: use of an electronic device to warn of intraoperative glove perforations.Ann R Coll Surg Engl. 1992 Sep;74(5):309-11. Ann R Coll Surg Engl. 1992. PMID: 1416699 Free PMC article.