A survey of the bacterial diversity in the cup filler of dental chair units
- PMID: 24031712
- PMCID: PMC3768761
- DOI: 10.1590/S1517-838220110003000015
A survey of the bacterial diversity in the cup filler of dental chair units
Abstract
Water from the cup filler of dental chair units (CFDC) was observed to contain sphingomonads, environmental mycobacteria and methylobacteria, among other minor bacteria. Some of the bacteria detected are recognized opportunistic pathogens. Some of these, tended to persist over time.
Keywords: Dental unit water; bacterial diversity; water safety.
Similar articles
-
Effective control of dental chair unit waterline biofilm and marked reduction of bacterial contamination of output water using two peroxide-based disinfectants.J Hosp Infect. 2002 Nov;52(3):192-205. doi: 10.1053/jhin.2002.1282. J Hosp Infect. 2002. PMID: 12419272
-
[Efficacy of Slightly Acidic Electrolyzed Water against Contamination of Water Line of Dental Units].Nihon Eiseigaku Zasshi. 2020;75(0). doi: 10.1265/jjh.19021. Nihon Eiseigaku Zasshi. 2020. PMID: 32213722 Japanese.
-
An Assessment of the Bacterial Diversity found in Dental Unit Waterlines using the Illumina MiSeq.Biocontrol Sci. 2019;24(4):201-212. doi: 10.4265/bio.24.201. Biocontrol Sci. 2019. PMID: 31875612
-
Biofilm problems in dental unit water systems and its practical control.J Appl Microbiol. 2009 May;106(5):1424-37. doi: 10.1111/j.1365-2672.2008.04100.x. Epub 2009 Feb 2. J Appl Microbiol. 2009. PMID: 19187140 Review.
-
Management of dental unit waterline biofilms in the 21st century.Future Microbiol. 2011 Oct;6(10):1209-26. doi: 10.2217/fmb.11.104. Future Microbiol. 2011. PMID: 22004039 Review.
Cited by
-
Water Contamination Risks at the Dental Clinic.Biology (Basel). 2020 Feb 27;9(3):43. doi: 10.3390/biology9030043. Biology (Basel). 2020. PMID: 32120909 Free PMC article.
-
Diversity and antibiotic resistance patterns of Sphingomonadaceae isolates from drinking water.Appl Environ Microbiol. 2011 Aug 15;77(16):5697-706. doi: 10.1128/AEM.00579-11. Epub 2011 Jun 24. Appl Environ Microbiol. 2011. PMID: 21705522 Free PMC article.
References
-
- Anesti V., McDonald I. R., Ramaswamy M., Wade W. G., Kelly D. P., Wood A. P. Isolation and molecular detection of methylotrophic bacteria occurring in the human mouth. Environ. Microbiol. 2005;7:1227–1238. - PubMed
-
- Casadevall A., Freundlich L. F., Pirofski L. Septic shock caused by Pseudomonas paucimobilis. Clin. Infec. Dis. 1992;14:784. - PubMed
-
- Ferreira da Silva M., Tiago I., Veríssimo A., Boaventura R.A.R., Nunes O.C., Manaia C.M. Antibiotic resistance of enterococci and related bacteria in an urban wastewater treatment plant. FEMS Microbiol. Ecol. 2006;55:322–329. - PubMed
LinkOut - more resources
Full Text Sources