Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2014 Jan:88:81-91.
doi: 10.1016/j.jpba.2013.08.032. Epub 2013 Aug 30.

Parallel achiral-chiral determination of oxybutynin, N-desethyl oxybutynin and their enantiomers in human plasma by LC-MS/MS to support a bioequivalence trial

Affiliations

Parallel achiral-chiral determination of oxybutynin, N-desethyl oxybutynin and their enantiomers in human plasma by LC-MS/MS to support a bioequivalence trial

Primal Sharma et al. J Pharm Biomed Anal. 2014 Jan.

Abstract

A parallel achiral and chiral determination of oxybutynin, its pharmacologically active metabolite N-desethyl oxybutynin and their enantiomers in human plasma is described using LC-MS/MS. Both the methods were developed and validated using deuterated analogues as internal standards. Achiral analysis of racemic oxybutynin and N-desethyl oxybutynin was carried out on Phenomenex Gemini C18 (150mm×4.6mm, 5μm) column under isocratic conditions using acetonitrile-5.0mM ammonium acetate, pH 4.0 (90:10, v/v) as the mobile phase. Separation of (S)- and (R)-enantiomers of the analytes was performed on Phenomenex Lux Amylose-2 (150mm×4.6mm, 3μm) chiral column using a mixture of solvent A [acetonitrile:10mM ammonium bicarbonate, 80:20 (v/v)] and solvent B [2-propanol:methanol, 50:50 (v/v)] in 20:80 (v/v) ratio as the mobile phase. Plasma samples were prepared by liquid-liquid extraction with ethyl acetate-diethyl ether-n-hexane solvent mixture. A linear range was established from 0.025 to 10.0ng/mL and 0.25 to 100ng/mL for the enantiomers of oxybutynin and N-desethyl oxybutynin respectively. The extraction recovery varied from 96.0 to 105.1%, while the IS-normalized matrix factors ranged from 0.96 to 1.07 for all the enantiomers. The validated method was applied for a pilot bioequivalence study with 5mg oxybutynin tablet formulation in 8 healthy subjects. The pharmacokinetic profiles showed that the plasma concentration of (R)-oxybutynin was lower than that of (S)-oxybutynin, while a reverse trend was observed for the enantiomers of N-desethyl oxybutynin. The reproducibility in the measurement of study data was demonstrated by reanalysis of 20 incurred samples.

Keywords: (S)- and (R)-N-Desethyl oxybutynin; (S)- and (R)-Oxybutynin; Achiral; Chiral; LC–MS/MS.

PubMed Disclaimer

LinkOut - more resources