Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2014 Feb;40(1):103-9.
doi: 10.1563/AAID-JOI-D-13-00232. Epub 2013 Sep 17.

Nanocrystalline hydroxyapatite-based material already contributes to implant stability after 3 months: a clinical and radiologic 3-year follow-up investigation

Affiliations
Randomized Controlled Trial

Nanocrystalline hydroxyapatite-based material already contributes to implant stability after 3 months: a clinical and radiologic 3-year follow-up investigation

Shahram Ghanaati et al. J Oral Implantol. 2014 Feb.

Abstract

The present study reports on a 3-year clinical and radiologic follow-up investigation of dental implants placed 3 and 6 months after sinus augmentation in 14 patients. Augmentation was performed with a synthetic bone substitute material composed of nanocrystalline hydroxyapatite. The aim of the study was to determine how the integration period of the bone substitute material, that is, 3 months or 6 months, influences implant integration within the patient's upper jaw. Therefore, the following clinical and radiologic parameters were investigated: implant being in situ; Periotest value; and presence of peri-implant osteolysis, bleeding on probing, plaque, and soft tissue recession around the implants. At the follow-up investigation 3 years after placement, 23 of 24 implants were in situ and suitable for prosthetic rehabilitation. No implants in either study group were mobile or showed peri-implant osteolysis. Only a few implants showed plaque or soft tissue variations. Within its limits, the present study showed comparable clinical performance of dental implants placed 3 months after sinus floor augmentation to implants placed 6 months after augmentation. The results of all investigated parameters were in accordance with results found in the literature. It can be concluded that augmentation with the applied synthetic bone substitute material already forms a sufficient implantation bed 3 months after augmentation, which enables long-term, stable, implant-retained restoration. These findings might contribute to a reduced healing time after augmentation, which would be favorable for patients and clinicians.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources