. 2014 Jun;27(3):219-26.
doi: 10.1007/s10334-013-0407-2. Epub 2013 Sep 18.

Increasing spatial resolution of 3T MRI scanning improves reproducibility of carotid arterial wall dimension measurements

Affiliations

Increasing spatial resolution of 3T MRI scanning improves reproducibility of carotid arterial wall dimension measurements

Diederik F van Wijk et al. MAGMA. 2014 Jun.

Abstract

Objective: To improve carotid 3T magnetic resonance imaging (MRI) dimension measurements in patients with overt atherosclerotic carotid artery disease.

Materials and methods: In 31 patients with advanced atherosclerotic carotid artery disease, two high resolution (0.25 × 0.25 mm(2); HR) and two routinely used low resolution (0.50 × 0.50 mm(2); LR) carotid 3T MRI scans were performed within 1 month. After manual delineation of carotid wall contours in a dedicated image analyses program in eight slices covering the atherosclerotic plaque, image reproducibility, as well as the within-reader and between-reader variability were determined.

Results: We found significantly higher intraclass correlation coefficients for total wall volume, mean wall area and mean wall thickness for the HR measurements (all p < 0.05). We found a significant lower signal-to-noise and contrast-to-noise ratio for the HR compared to the LR measurements. The carotid arterial wall dimension measurements of all parameters were significantly lower for the HR compared to the LR measurements. No significant differences were observed between the within-reader and between-reader reproducibility for HR versus LR measurements.

Conclusion: Increasing the in-plane resolution improves the reproducibility of 3T MRI carotid arterial wall dimension measurements. The use of HR imaging will contribute to a reduced sample size needed in intervention trials using MRI scanning of the carotid artery as surrogate marker for atherosclerosis progression.

PubMed Disclaimer

Similar articles

Cited by

References

    1. JAMA. 2009 Mar 18;301(11):1131-9 - PubMed
    1. N Engl J Med. 2008 Apr 3;358(14):1431-43 - PubMed
    1. Circ Cardiovasc Imaging. 2009 May;2(3):235-42 - PubMed
    1. J Magn Reson Imaging. 2006 May;23(5):699-705 - PubMed
    1. J Magn Reson Imaging. 2007 May;25(5):1035-43 - PubMed

Publication types

LinkOut - more resources