Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2013 Oct 10;232(1-3):111-24.
doi: 10.1016/j.forsciint.2013.07.013. Epub 2013 Aug 9.

Towards the integration of matrix assisted laser desorption ionisation mass spectrometry imaging into the current fingermark examination workflow

Affiliations

Towards the integration of matrix assisted laser desorption ionisation mass spectrometry imaging into the current fingermark examination workflow

Robert Bradshaw et al. Forensic Sci Int. .

Abstract

A wide range of fingermark enhancement techniques (FET) is currently employed to visualise latent fingermarks at crime scenes. However, if smudged, partial, distorted or absent in the National Fingerprint Database, crime scene marks may be not useful for identification purposes. In these circumstances, a technology enabling chemical imaging of both endogenous and exogenous species contained within the fingermark could provide additional and associative investigative information, to profile the suspect's activities prior to the crime. Matrix Assisted Laser Desorption Ionisation Mass Spectrometry Imaging (MALDI MSI) has proven to be such a technique, enabling investigative information to be gathered, for example, on what substances the donor has come in contact with and what they have ingested. Nonetheless, to be employed, MALDI MSI has to be validated and its compatibility with FET tested for integration into the standard fingermark examination workflow. For the first time, a direct comparison has been made between the efficiency of a range of FET and MALDI MSI under different conditions. This information will build towards validation of the technology. Also, for the first time, MALDI MSI has been successfully employed as a sequential step following fingermark enhancement using many of the currently employed FET. Additionally, known enhancers have been "re-visited" by combining them with a MALDI matrix, providing both improved fingermark development and chemical species detection via MALDI MSI. The result reported here are good indication in favour of the integration of MALDI MSI into the current fingermark examination workflow for gathering additional investigative information.

Keywords: Development enhancers; Fingermarks; Forensic workflow; Integration; Intelligence; MALDI MSI.

PubMed Disclaimer

Publication types

LinkOut - more resources