Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2014 Jan;21(1):6-11.
doi: 10.1016/j.jocn.2013.03.014. Epub 2013 Sep 19.

Treatment of unruptured intracranial aneurysms with the pipeline embolization device

Affiliations

Treatment of unruptured intracranial aneurysms with the pipeline embolization device

Santosh B Murthy et al. J Clin Neurosci. 2014 Jan.

Abstract

The pipeline embolization device (PED; ev3 Endovascular, Plymouth, MN, USA) is a flow-diverter used in the endovascular treatment of intracranial aneurysms, particularly those with unfavorable configurations. It causes progressive flow redirection leading to aneurysm thrombosis. This study aimed to present a systematic review of the published literature on the clinical outcomes of PED. A Medline search of the English language literature was performed using the keywords "intracranial aneurysms" and "pipeline embolization device" or "flow diverters". The inclusion criteria were: n>10 patients; unruptured aneurysms; documentation of complications; and at least 3 months of follow-up. A total of 13 studies, with 905 patients and 1043 aneurysms, were included. The mean age was 53.8 years, with women comprising 76.3% of patients. The mean aneurysm diameter was 11.1mm with 37% classed as large aneurysms and 10% classed as giant. The cumulative mortality rate was 2.3%. Seventeen patients had a stroke (1.9%), while 19 (2.0%) had a transient ischemic attack and 21 patients (2.3%) had an intracranial hemorrhage. The two outcome measures were the cumulative event rate (16.7%) and the 6 month aneurysm occlusion rate (79.7%). A funnel plot with study size plotted against the two outcome measures revealed publication bias. Data from recent studies suggest that complication and mortality rates associated with PED may be similar to other contemporary endovascular techniques, with a better 6 month aneurysm occlusion rate. More prospective clinical trials are warranted to further validate these results.

Keywords: Intracranial aneurysms; Pipeline embolization device; Stents; Subarachnoid hemorrhage; Unruptured.

PubMed Disclaimer

Publication types

LinkOut - more resources