Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2013 Dec:47:113-20.
doi: 10.1016/j.compbiolchem.2013.08.008. Epub 2013 Sep 4.

In vitro cytotoxicity assessment based on KC(50) with real-time cell analyzer (RTCA) assay

Affiliations

In vitro cytotoxicity assessment based on KC(50) with real-time cell analyzer (RTCA) assay

Tianhong Pan et al. Comput Biol Chem. 2013 Dec.

Abstract

Technological advances in cytotoxicity analysis have now made it possible to obtain real time data on changes in cell growth, morphology and cell death. This type of testing has a great potential for reducing and refining traditional in vivo toxicology tests. By monitoring the dynamic response profile of living cells via the xCELLigence real-time cell analyzer for high-throughput (RTCA HT) system, cellular changes including cell number (cell index, CI) are recorded and analyzed. A special scaled index defined as normalized cell index (NCI) is used in the analysis which reduces the influence of inter-experimental variations. To assess the extent of exposure of the tested chemicals, a two-exponent model is presented to describe rate of cell growth and death. This model is embodied in the time and concentration-dependent cellular response curves, and the parameters k1 and k2 in this model are used to describe the rate of cell growth and death. Based on calculated k2 values and the corresponding concentrations, a concentration-response curve is fitted. As a result, a cytotoxicity assessment named KC50 is calculated. The validation of the proposed method is demonstrated by exposing six cell lines to 14 chemical compounds. Our findings suggest that the proposed KC50-based toxicity assay can be an alternative to the traditional single time-point assay such as LC50 (the concentration at which 50% of the cells are killed). The proposed index has a potential for routine evaluation of cytotoxicities. Another advantage of the proposed index is that it extracts cytotoxicity information when CI fails to detect the low toxicity.

Keywords: High-throughput screening (HTS); In vitro cytotoxicity assessment; Regression analysis; Time-dependent cellular response profile (TCRP).

PubMed Disclaimer

Publication types

LinkOut - more resources