Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2013 Nov;55(11):1373-8.
doi: 10.1007/s00234-013-1277-z. Epub 2013 Sep 22.

Solitaire AB stent-assisted coiling of wide-necked intracranial aneurysms: short-term results from a prospective, consecutive, European multicentric study

Affiliations
Clinical Trial

Solitaire AB stent-assisted coiling of wide-necked intracranial aneurysms: short-term results from a prospective, consecutive, European multicentric study

Benjamin Gory et al. Neuroradiology. 2013 Nov.

Abstract

Introduction: Solitaire AB stent-assisted coiling facilitates the endovascular treatment of wide-necked intracranial aneurysms. Solitaire Aneurysm Remodeling is the first prospective, consecutive, European multicentric study whose main objective was to evaluate the safety, short-, and long-term efficacy of the Solitaire AB stent. This first analysis is focused on the short-term results.

Methods: After exclusion of one patient, 66 Solitaire AB stents were used to treat via endovascular approach 64 aneurysms (63 patients) in seven European centers. Technical and clinical complications were recorded. A core laboratory evaluated the angiographic efficacy by using the Raymond classification scale.

Results: The mean width of aneurysm sac was 7.5 mm, and the mean diameter of aneurysm neck was 4.7 mm. Complete occlusion was achieved in 27 aneurysms (42.2 %); neck remnant was seen in 25 aneurysms (39.1 %) and aneurysm remnant in 12 aneurysms (18.7 %). Technical and clinical complications related to the procedure were encountered in eight patients (12.7 %). Postprocedural modification of the clinical status was observed in one patient (1.6 %). No patients died (0 %); one had a permanent deficit (1.6 %), and one had a transient deficit (1.6 %). Treatment-related mortality was 0 %, and permanent morbidity was 1.6 %.

Conclusion: The Solitaire AB stent has an excellent rate of technical success navigation with the absence of dislodgement. The safety and short-term efficacy are comparable to those previously reported with coiling alone. Mid- and long-term follow-up will be required to elucidate the impact of the Solitaire AB stent on recanalization rate.

PubMed Disclaimer

References

    1. Neurosurgery. 2012 Jun;70(6):1415-29; discussion 1429 - PubMed
    1. Neuroradiology. 2011 Mar;53(3):193-5 - PubMed
    1. AJNR Am J Neuroradiol. 2006 Sep;27(8):1693-9 - PubMed
    1. AJNR Am J Neuroradiol. 2013 Jul;34(7):1380-4 - PubMed
    1. AJNR Am J Neuroradiol. 2008 Apr;29(4):786-91 - PubMed

MeSH terms

LinkOut - more resources