Intra- and post-operative accuracy assessments of two different patient-specific instrumentation systems for total knee replacement

Affiliations
Randomized Controlled Trial

Intra- and post-operative accuracy assessments of two different patient-specific instrumentation systems for total knee replacement

Andrea Ensini et al. Knee Surg Sports Traumatol Arthrosc. 2014 Mar.

Abstract

Purpose: The aim of this study is to assess and compare the accuracy of two different patient-specific instrumentation (PSI) systems for total knee replacement, both intra-operatively for bone preparation and post-operatively for final component alignment.

Methods: Twenty-five patients were treated according to a computer tomography (CT)-based PSI system (group A) and 25 to a magnetic resonance imaging (MRI)/X-ray-based system (group B). Alignments on the three anatomical planes and resection thickness at the cutting blocks and at the resulting bone cuts were recorded intra-operatively by a standard surgical navigation system. Alignments of the prosthetic components and mechanical axis were also measured post-operatively on radiographs. These measurements at both the femur and tibia were compared with those of the corresponding pre-operative planning, considering discrepancies larger than 3° as outliers.

Results: In both groups, the mean absolute differences between pre-operatively planned alignments and corresponding intra- and post-operative measurements ranged from a minimum of 1.2° to a maximum of 2.9° in all three anatomical planes. In both groups and in both femur and tibia, the plane with the smallest percentage of outliers was the coronal, maximum 17%. The comparison between two groups was statistically significant (p = 0.02) in the femoral sagittal plane, where group B showed smaller alignment discrepancies at the cutting blocks.

Conclusions: Both PSI systems showed good alignments in the coronal plane in all stages. For a few measurements, a better performance was observed in the MRI/X-ray-based system than in the CT-based system.

Level of evidence: I.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Clin Orthop Relat Res. 2004 Nov;(428):131-9 - PubMed
    1. Knee Surg Sports Traumatol Arthrosc. 2013 Oct;21(10):2194-9 - PubMed
    1. Orthop Traumatol Surg Res. 2009 Sep;95(5):365-72 - PubMed
    1. Public Health Rep. 2005 May-Jun;120(3):278-82 - PubMed
    1. Knee Surg Sports Traumatol Arthrosc. 2012 Sep;20(9):1815-21 - PubMed

Publication types