Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comment
. 2013 Sep;14(3):78-80.
doi: 10.1038/sj.ebd.6400950.

Low quality evidence on the stability of orthodontic mini-implants

Affiliations
Comment

Low quality evidence on the stability of orthodontic mini-implants

Reint Meursinge Reynders. Evid Based Dent. 2013 Sep.

Abstract

Data sources: Medline, Embase, LILACS, Cochrane Library, Google Scholar, Web of Science, African Journals Online, Digital Dissertations.

Study selection: Randomised controlled trials (RCTs), prospective controlled clinical trials(CCTs) and prospective cohort studies were included. Studies on implants with a diameter greater than 2 mm were excluded.

Data extraction and synthesis: Data were extracted independently by two authors. Bias in RCTs was assessed using the Cochrane risk of bias tool, with non-randomised studies being assessed using the Newcastle-Ottawa Scale. Failures of mini-screw implants were expressed as event rates with 95% confidence intervals. Risk factors were assessed using random effects model and sub-group and meta-regression analyses were also conducted.

Results: Fifty-two studies; five RCTs, eight CCTs, twenty-seven prospective cohort studies and twelve studies with unclear designs that were assessed to be prospective cohort studies were included. A funnel plot suggested there may be publication bias. Analysis of 4987 miniscrew implants used in 2281 patients indicated an overall failure rate of 13.5% (95% confidence interval, 11.5%-15.8%). Failures were not associated with patient sex or age and mini-screw implant insertion side, whereas they were significantly associated with jaw of insertion. Some trends were identified through exploratory analysis but no definite conclusions could be drawn.

Conclusions: Orthodontic miniscrew implants have a modest small mean failure rate, indicating their usefulness in clinical practice. Although many factors seem to affect their failure rates, the majority of them still need additional evidence to support any possible associations.

PubMed Disclaimer

Comment on

MeSH terms

LinkOut - more resources