The pros and cons of using larger femoral heads in total hip arthroplasty
- PMID: 24078959
The pros and cons of using larger femoral heads in total hip arthroplasty
Abstract
With the introduction of improved bearing surfaces for total hip arthroplasty (THA) has come a reintroduction of larger femoral heads with the promise of reducing the rate of hip instability and increasing hip range of motion (ROM). The size of femoral heads used for THA ranges from 22 to 40 mm, and even larger heads are used for hip resurfacing. With accurately positioned components, larger heads reduce the hip instability rate and theoretically increase hip ROM. However, for any given bearing surface, the volumetric wear rate is higher for larger heads than for smaller heads, which potentially jeopardizes the long-term survival of these reconstructions. In this article, we review the evidence for use of larger femoral heads with respect to stability, ROM, impingement, wear rate, bearing surfaces, and future directions.
Similar articles
-
Large-diameter femoral heads in total hip arthroplasty: an evidence-based review.Am J Orthop (Belle Mead NJ). 2014 Nov;43(11):506-12. Am J Orthop (Belle Mead NJ). 2014. PMID: 25379747 Review.
-
Have large femoral heads reduced prosthetic impingement in total hip arthroplasty?Hip Int. 2019 Jan;29(1):83-88. doi: 10.1177/1120700018761153. Epub 2018 May 7. Hip Int. 2019. PMID: 29734855
-
Use of modular large femoral heads without liners in hip arthroplasty.Surg Technol Int. 2006;15:217-20. Surg Technol Int. 2006. PMID: 17029179 Review.
-
Is Oxidized Zirconium Femoral Head Superior to Other Bearing Types in Total Hip Arthroplasty? A Systematic Review and Meta-Analysis.J Arthroplasty. 2019 Aug;34(8):1844-1852. doi: 10.1016/j.arth.2019.03.072. Epub 2019 Apr 2. J Arthroplasty. 2019. PMID: 31010775
-
Early outcomes of sequentially cross-linked thin polyethylene liners with large diameter femoral heads in total hip arthroplasty.Bull NYU Hosp Jt Dis. 2011;69 Suppl 1:S90-4. Bull NYU Hosp Jt Dis. 2011. PMID: 22035492
Cited by
-
Results of Primary Total Hip Arthroplasty with 36-mm Femoral Heads on Highly Cross-linked Polyethylene-Minimum Seven-years Follow-up.Hip Pelvis. 2014 Dec;26(4):220-6. doi: 10.5371/hp.2014.26.4.220. Epub 2014 Dec 31. Hip Pelvis. 2014. PMID: 27536585 Free PMC article.
-
Biomechanical Substantiation of the Strength and Stiffness of a Hip Joint Capsule Defect Fixation with Polypropylene Mesh.Surg J (N Y). 2020 Jan 21;6(1):e11-e18. doi: 10.1055/s-0039-3402793. eCollection 2020 Jan. Surg J (N Y). 2020. PMID: 31970288 Free PMC article.
-
Large Diameter Head in Primary Total Hip Arthroplasty: A Systematic Review.Indian J Orthop. 2020 May 29;54(6):784-794. doi: 10.1007/s43465-020-00146-y. eCollection 2020 Nov. Indian J Orthop. 2020. PMID: 33133401 Free PMC article. Review.
-
Hip stability parameters with dual mobility, modular dual mobility and fixed bearing in total hip arthroplasty: an analytical evaluation.BMC Musculoskelet Disord. 2022 Apr 20;23(1):373. doi: 10.1186/s12891-022-05280-2. BMC Musculoskelet Disord. 2022. PMID: 35443656 Free PMC article.
-
Catastrophic Early Failure and Fragmentation of a Modern Moderately Cross-linked Polyethylene Acetabular Liner.Arthroplast Today. 2023 Jul 24;22:101161. doi: 10.1016/j.artd.2023.101161. eCollection 2023 Aug. Arthroplast Today. 2023. PMID: 37521736 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Medical
Miscellaneous