Superior sensitivity and decreased time to detection with the Bactec Peds Plus/F system compared to the BacT/Alert Pediatric FAN blood culture system
- PMID: 24088854
- PMCID: PMC3838080
- DOI: 10.1128/JCM.02205-13
Superior sensitivity and decreased time to detection with the Bactec Peds Plus/F system compared to the BacT/Alert Pediatric FAN blood culture system
Abstract
Here, we compare the sensitivities and times to detection (TTD) of BacT/Alert Pediatric FAN (PF) and Bactec Peds Plus blood culture bottles. Test bottles were inoculated with 2 ml of banked whole blood, 1-ml aliquots of antibiotic suspension, and organisms diluted to simulate a bacteremia level of 10 to 100 CFU/ml. The control bottles were inoculated with 3 ml of banked blood and organism suspensions only. The organism-drug combinations were Staphylococcus epidermidis and vancomycin, methicillin-resistant Staphylococcus aureus and vancomycin, Streptococcus pneumoniae, vancomycin, and ceftriaxone, Streptococcus agalactiae, ampicillin, and cefotaxime, Escherichia coli, cefotaxime, and cefepime, Pseudomonas aeruginosa, piperacillin-tazobactam, cefepime, and gentamicin, Neisseria meningitidis and ceftriaxone, and Haemophilus influenzae and ceftriaxone. The control and test bottle combinations were tested in duplicate. The bottles were incubated for 5 days; 32 control and 104 test bottles were incubated. Overall, the bacterial recovery rates for the PF and Peds Plus bottles were 37% and 62%, 94% and 100% in the controls, 19% and 50% in the test bottles, and 33% and 92% in the bottles with vancomycin, respectively. No bacteria were recovered from the bottles with S. pneumoniae, S. agalactiae, E. coli, N. meningitidis, or H. influenzae in combination with cefotaxime or ceftriaxone. The Peds Plus system detected P. aeruginosa in bottles with cefepime and piperacillin-tazobactam, but the PF system recovered bacteria only in bottles with trough levels of piperacillin-tazobactam. The mean TTD were shorter in the Peds Plus system controls (14.2 versus 18.0 h; P = 0.001) and the test bottles (14.3 versus 17.8 h; P = 0.008) than in the PF bottles. Overall, we demonstrated superior sensitivity, TTD, and antibiotic neutralization in the Bactec Peds Plus system compared to those in the Pediatric FAN system.
References
-
- Schifman RB, Bachner P, Howanitz PJ. 1996. Blood culture quality improvement: a College of American Pathologists Q-Probes study involving 909 institutions and 289 572 blood culture sets. Arch. Pathol. Lab. Med. 120:999–1002 - PubMed
-
- Clinical and Laboratory Standards Institute 2009. Principles and procedures for blood cultures. Approved guideline, vol 27, no. 18 CLSI document M47-A Clinical and Laboratory Standards Institute, Wayne, PA
-
- Cockerill FR, III, Wilson JW, Vetter EA, Goodman KM, Torgerson CA, Harmsen WS, Schleck CD, Ilstrup DM, Washington JA, II, Wilson WR. 2004. Optimal testing parameters for blood cultures. Clin. Infect. Dis. 38:1724–1730 - PubMed
-
- Linderkamp O, Versmold HT, Riegel KP, Betke K. 1977. Estimation and prediction of blood volume in infants and children. Eur. J. Pediatr. 125:227–234 - PubMed
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Molecular Biology Databases
Research Materials
