Probing with the ventilator
- PMID: 24090345
- PMCID: PMC4056809
- DOI: 10.1186/cc13038
Probing with the ventilator
Abstract
Neurally adjusted ventilatory assist operates through recordings of electrical activity of the diaphragm (EAdi). Barwing and colleagues found increases in EAdi in weaning-failure patients, although the values were not significantly different from weaning-success patients. Future studies will need to carefully control for the considerable biological noise evident in EAdi recordings.
Comment on
-
Electrical activity of the diaphragm (EAdi) as a monitoring parameter in difficult weaning from respirator: a pilot study.Crit Care. 2013 Aug 28;17(4):R182. doi: 10.1186/cc12865. Crit Care. 2013. PMID: 23985299 Free PMC article.
References
-
- Tobin MJ, Jubran A. In: Principles and Practice of Mechanical Ventilation. 3. Tobin MJ, editor. New York: McGraw-Hill, Inc; 2012. Weaning from mechanical ventilation; pp. 1185–1220.
-
- Tobin MJ, Guenther SM, Perez W, Mador MJ, Semmes BJ, Allen SJ, Lodato RF, Dantzker DR. The pattern of breathing during successful and unsuccessful trials of weaning from mechanical ventilation. Am Rev Respir Dis. 1986;17:1111–1118. - PubMed
-
- Sinderby C, Beck JC. In: Principles and Practice of Mechanical Ventilation. 3. Tobin MJ, editor. New York: McGraw-Hill, Inc; 2012. Neurally adjusted ventilatory assist; pp. 351–375.
-
- Tobin MJ, Laghi F, Jubran A. Ventilatory failure, ventilator support and ventilator weaning. Compr Physiol. 2012;17:2871–2921. - PubMed
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources