Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2014 Jan;164(1):46-51.
doi: 10.1016/j.jpeds.2013.08.040. Epub 2013 Oct 1.

A randomized controlled trial of two nasal continuous positive airway pressure levels after extubation in preterm infants

Affiliations
Randomized Controlled Trial

A randomized controlled trial of two nasal continuous positive airway pressure levels after extubation in preterm infants

Bridget Buzzella et al. J Pediatr. 2014 Jan.

Abstract

Objective: To compare extubation failure rate with two ranges of nasal continuous positive airway pressure (NCPAP) in oxygen dependent preterm infants.

Study design: Preterm infants of birth weight 500-1000 g and gestational age 23-30 weeks, extubated for the first time during the first 6 weeks while requiring fraction of inspired oxygen ≥ 0.25, were randomly assigned to a NCPAP range of 4-6 (low NCPAP) or 7-9 (high NCPAP) cmH2O.

Results: Infants were randomized to low (n = 47) or high NCPAP (n = 46) at day 16.3 ± 14.7 and 15.5 ± 12.4, respectively. Rates of extubation failure per criteria (24% vs 43%, P = .04, OR and 95% CI: 0.39 [0.16-0.96]) and re-intubation (17% vs 38%, P = .023, 0.33 [0.016-0.85]) within 96 hours were significantly lower in the high- compared with the low NCPAP group. This was mainly due to a strikingly lower failure rate in the 500-750 g birth weight strata. Duration of ventilation, bronchopulmonary dysplasia, or severe bronchopulmonary dysplasia did not differ significantly. No infant developed pneumothorax during 96 hours post-extubation.

Conclusions: Extubation failure in preterm infants with residual lung disease was lower with NCPAP range of 7-9 compared with 4-6 cmH2O. These findings suggest the need for higher distending pressure post-extubation in the more immature infants who are still oxygen dependent.

Keywords: BPD; BW; Birth weight; Bronchopulmonary dysplasia; FiO(2); Fraction of inspired oxygen; GA; Gestational age; NCPAP; NICU; Nasal continuous positive airway pressure; Neonatal intensive care unit; PDA; PMA; Patent ductus arteriosus; Post-menstrual age.

PubMed Disclaimer

Publication types