. 2014 Mar;17(1):16-22.
doi: 10.1007/s10047-013-0731-3. Epub 2013 Oct 6.

Paracorporeal ventricular assist device as a bridge to transplant candidacy in the era of implantable continuous-flow ventricular assist device

Affiliations

Paracorporeal ventricular assist device as a bridge to transplant candidacy in the era of implantable continuous-flow ventricular assist device

Hideaki Suwa et al. J Artif Organs. 2014 Mar.

Abstract

Ventricular assist devices (VADs) have long been used as bridge to transplant therapy (BTT). Nipro-Toyobo paracorporeal pulsatile-flow VAD (nt-VAD) was the only device available until April 2011, when implantable continuous-flow VADs (cf-VADs) became available. Although cf-VADs are central to BTT, nt-VAD remains a necessary option. We aimed to clarify the role of nt-VAD in an era of increasing cf-VAD use. We retrospectively reviewed patients who underwent VAD implantation at the National Cerebral and Cardiovascular Center from May 2011 to March 2013. Characteristics were compared between the nt-VAD and cf-VAD groups. Twenty-nine patients (mean age 37.7 ± 11.1 years, 23 males) underwent VAD implantation. Fifteen patients initially received nt-VADs, although 4 were converted to cf-VADs. Of these 15 patients, 3 were too small for cf-VADs and 2 needed bilateral ventricular support. The remaining 10 patients received nt-VADs (7 patients at INTERMACS level 1 and 3 at level 2). The nt-VAD group patients had significantly more preoperative mechanical circulatory support and were in a more critical condition before VAD implantation than the cf-VAD group. The 2-year survival rate was not significantly different. Despite the critical conditions of nt-VAD patients, their overall survival is not statistically inferior to that of cf-VAD patients. nt-VAD is a good option as a BTC for the patient with urgent and critical condition.

PubMed Disclaimer

References

    1. J Heart Lung Transplant. 2011 Feb;30(2):115-23 - PubMed
    1. J Thorac Cardiovasc Surg. 2007 Aug;134(2):351-8 - PubMed
    1. N Engl J Med. 2009 Dec 03;361(23):2241-51 - PubMed
    1. J Heart Lung Transplant. 2012 Jun;31(6):618-24 - PubMed
    1. J Heart Lung Transplant. 2012 Feb;31(2):117-26 - PubMed

LinkOut - more resources