. 2014 Jan;58(1):56-61.
doi: 10.1007/s10384-013-0280-6. Epub 2013 Oct 8.

Intraobserver and interobserver agreement of computer software-assisted optic nerve head photoplanimetry

Affiliations

Intraobserver and interobserver agreement of computer software-assisted optic nerve head photoplanimetry

Masaki Tanito et al. Jpn J Ophthalmol. 2014 Jan.

Abstract

Purpose: To report the reproducibility profile of optic nerve head parameters obtained by computer software-assisted fundus photoplanimetry.

Methods: Fundus photographs obtained during a population-based health survey (Sakurae Study) were planimetrically analyzed using newly developed computer software, CDSketch. The parameters assessed included vertical and horizontal cup-to-disc (C/D) ratios, superior and inferior rim-to-disc (R/D) ratios, disc and cup vertical-to-horizontal (V/H) ratios, and disc-macular distance-to-disc diameter (DM/DD) ratio. For intraobserver and interobserver agreement assessments, we calculated the coefficients of variation (CVs) and intraclass correlation coefficients (ICCs) of the mean of three measurements obtained by one observer and a one-time measurement by three observers, respectively.

Results: The intraobserver CVs were between 2.4 % (DM/DD ratio) and 11.0 % (inferior R/D ratio), and the ICCs were between 0.868 (cup V/H ratio) and 0.976 (DM/DD ratio); all intraobserver ICCs had almost perfect agreement (>0.81). The interobserver CVs were between 2.6 % (disc V/H ratio) and 18.0 % (inferior R/D ratio), and the ICCs were between 0.762 (cup V/H ratio) and 0.930 (DM/DD ratio); the interobserver ICCs were categorized as substantial (0.61-0.80) for the inferior R/D and cup V/H ratios and as almost perfect for the other five parameters.

Conclusions: The consistent profiles of the planimetric parameters suggest the suitability of software-assisted photoplanimetry for assessing optic disc characteristics in glaucoma clinical study and practice.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Invest Ophthalmol Vis Sci. 2007 Mar;48(3):1156-63 - PubMed
    1. Invest Ophthalmol Vis Sci. 2010 Nov;51(11):5724-30 - PubMed
    1. Jpn J Ophthalmol. 2003 Mar-Apr;47(2):214-20 - PubMed
    1. Ophthalmologica. 2013;229(2):101-5 - PubMed
    1. Ophthalmology. 2012 Jun;119(6):1134-42 - PubMed

Publication types

MeSH terms

LinkOut - more resources