Randomized Controlled Trial
. 2013 Nov;15(11):839-44.
doi: 10.1111/jch.12203. Epub 2013 Sep 19.

Simultaneous compared with sequential blood pressure measurement results in smaller inter-arm blood pressure differences

Affiliations
Randomized Controlled Trial

Simultaneous compared with sequential blood pressure measurement results in smaller inter-arm blood pressure differences

Niels V van der Hoeven et al. J Clin Hypertens (Greenwich). 2013 Nov.

Abstract

There are currently few recommendations on how to assess inter-arm blood pressure (BP) differences. The authors compared simultaneous with sequential measurement on mean BP, inter-arm BP differences, and within-visit reproducibility in 240 patients stratified according to age (<50 or ≥60 years) and BP (<140/90 mm Hg or ≥140/90 mm Hg). Three simultaneous and three sequential BP measurements were taken in each patient. Starting measurement type and starting arm for sequential measurements were randomized. Mean BP and inter-arm BP differences of the first pair and reproducibility of inter-arm BP differences of the first and second pair were compared between both methods. Mean systolic BP was 1.3±7.5 mm Hg lower during sequential compared with simultaneous measurement (P<.01). However, the first sequential measurement was on average higher than the second, suggesting an order effect. Absolute systolic inter-arm BP differences were smaller on simultaneous (6.2±6.7/3.3±3.5 mm Hg) compared with sequential BP measurement (7.8±7.3/4.6±5.6 mm Hg, P<.01 for both). Within-visit reproducibility was identical (both r=0.60). Simultaneous measurement of BP at both arms reduces order effects and results in smaller inter-arm BP differences, thereby potentially reducing unnecessary referral and diagnostic procedures.

PubMed Disclaimer

Figures

Figure
Figure
Bland‐Altman plot for inter‐arm blood pressure (BP) differences of simultaneous (a) and sequential (b) BP assessment.

Comment in

  • Inter-arm blood pressure difference.
    Bursztyn M. Bursztyn M. J Clin Hypertens (Greenwich). 2013 Nov;15(11):774-5. doi: 10.1111/jch.12216. Epub 2013 Oct 21. J Clin Hypertens (Greenwich). 2013. PMID: 24148200 Free PMC article. No abstract available.

References

    1. Cyriax E. Unilateral alterations in blood pressure: the differential blood‐pressure sign (second communication). Q J Med. 1921;14:309–313.
    1. National Institute for Health and Clinical Excellence . Hypertension: the clinical management of primary hypertension in adults, CG127. NICE, 2011. 2011.
    1. Mancia G, Fagard R, Narkiewicz K, et al. 2013 ESH/ESC Guidelines for the management of arterial hypertension: the Task Force for the management of arterial hypertension of the European Society of Hypertension (ESH) of the European Society of Cardiology (ESC). Eur Heart J. 2013;34:2159–2219. - PubMed
    1. Aboyans V, Criqui MH, McDermott MM, et al. The vital prognosis of subclavian stenosis. J Am Coll Cardiol. 2007;49:1540–1545. - PubMed
    1. Aboyans V, Kamineni A, Allison MA, et al. The epidemiology of subclavian stenosis and its association with markers of subclinical atherosclerosis: the Multi‐Ethnic Study of Atherosclerosis (MESA). Atherosclerosis. 2010;211:266–270. - PMC - PubMed

Publication types