Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2013 Dec;54(9):719-36.
doi: 10.1002/em.21812. Epub 2013 Sep 16.

Bioassay-directed fractionation and sub-fractionation for mutagenicity and chemical analysis of diesel exhaust particles

Affiliations

Bioassay-directed fractionation and sub-fractionation for mutagenicity and chemical analysis of diesel exhaust particles

Esra Mutlu et al. Environ Mol Mutagen. 2013 Dec.

Abstract

Several types of diesel exhaust particles (DEPs) have been used for toxicology studies, including a high-organic automobile DEP (A-DEP) from Japan, and a low-organic forklift DEP developed by the National Institute of Standards and Technology (N-DEP). However, these DEPs were not characterized extensively for chemical composition or sub-fractionated and tested extensively for mutagenicity. We collected a compressor-generated DEP (C-DEP) and characterized it by conducting bioassay-directed fractionation of the extractable organics in Salmonella and correlating the results by hierarchical clustering with the concentrations of 32 polycyclic aromatic hydrocarbons (PAHs). Relative to A- and N-DEP, the mutagenic potency of C-DEP was intermediate in TA100 +S9 (PAH mutagenicity) but was lowest in TA98 -S9 (nitroarene mutagenicity). More than 50% of the mass of the extractable organics of C-DEP eluted in the nonpolar Fraction 1, and only ∼20% eluted in the moderately polar Fractions 2 and 3. However, most of the mutagenicity eluted in Fractions 2 and 3, similar to A-DEP but different from N-DEP. HPLC-derived mutagrams of 62 sub-fractions per fraction confirmed that most of the mutagenicity was due to moderately polar compounds. The diagnostic strains identified a strong role for PAHs, nitroarenes, aromatic amines, and oxy-PAHs in the mutagenicity of C-DEP. Hierarchical clustering confirmed the importance of oxy-PAHs but not that of nitroarenes. To our knowledge this is the first use of hierarchical clustering to correlate chemical composition with the mutagenicity of a complex mixture. The chemical analysis and mutagenicity of C-DEP described here makes C-DEP suitable for additional toxicological studies.

Keywords: Salmonella; combustion emissions; complex mixtures.

PubMed Disclaimer

Similar articles

Cited by

MeSH terms

LinkOut - more resources