Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2013 Dec:58 Suppl 1:e97-e103.
doi: 10.1016/j.jcv.2013.08.021. Epub 2013 Aug 30.

Evaluation of the Bio-Rad Multispot HIV-1/HIV-2 Rapid Test as an alternative to Western blot for confirmation of HIV infection

Affiliations
Comparative Study

Evaluation of the Bio-Rad Multispot HIV-1/HIV-2 Rapid Test as an alternative to Western blot for confirmation of HIV infection

Ana María Cárdenas et al. J Clin Virol. 2013 Dec.

Abstract

Background: In the United States, a new HIV diagnostic algorithm has been proposed that uses an HIV-1/HIV-2 antibody differentiation immunoassay instead of Western blot or immunofluoresence for confirmatory testing.

Objectives: To evaluate the Multispot HIV-1/HIV-2 Rapid Test (Multispot) as an alternative to Western blot analysis for confirmation of HIV infection.

Study design: A series of 205 serum and plasma specimens positive for HIV-1 or HIV-2 were used to compare the performance of Multispot to a standard HIV-1 Western blot. Positive samples included 63 specimens from patients>18 months of age, 33 proficiency survey specimens, and 109 specimens from nine commercial seroconversion and performance panels. In addition, 63 specimens from 51 HIV-exposed, uninfected children≤18 months of age in various stages of seroreversion and 192 HIV-negative samples were tested. Specimens were initially screened using a 4th generation HIV Ag/Ab Combo assay.

Results: Multispot readily discriminated between individuals with HIV-1 or HIV-2 infection and those who were uninfected. Of the 205 samples repeatedly reactive by the 4th generation screening assay, infection status was correctly confirmed by Multispot in 83.9% (172/205) compared to 68.8% (141/205) for Western blot. Multispot detected HIV-1 earlier in 27.6% of low-titer antibody specimens called indeterminate by Western blot, and effectively reduced the number of indeterminate results in seroreverting HIV-1 exposed, uninfected infants and for HIV-2 infections misinterpreted as indeterminate or positive by HIV-1 Western blot.

Conclusions: Multispot offers speed and simplicity over Western blot and has an excellent performance for differentiation and confirmation of antibodies to HIV-1 and HIV-2.

Keywords: Algorithm; CAP; CRF; College of American Pathology; Diagnosis; HIV; Ind; ND; NR; Neg; Pos; R; Rapid test; Western blot; circulating recombinant forms; indeterminate; mo.; months; negative; nonreactive; not done; positive; reactive.

PubMed Disclaimer

Similar articles

Cited by

LinkOut - more resources