Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Observational Study
. 2014 Sep;92(6):529-34.
doi: 10.1111/aos.12276. Epub 2013 Oct 7.

Glistening in glaucomatous eyes: visual performances and risk factors

Affiliations
Free article
Observational Study

Glistening in glaucomatous eyes: visual performances and risk factors

Cedric Schweitzer et al. Acta Ophthalmol. 2014 Sep.
Free article

Abstract

Purpose: To analyse risk factors and visual performances of glaucomatous eyes with glistening in the intra-ocular lens (IOL).

Methods: Prospective study performed between November 2010 and April 2011 and involving 67 consecutive glaucomatous eyes (47 patients), who previously had a phacoemulsification with a hydrophobic acrylic IOL implanted in the capsular bag. Glistening was classified in three groups of severity grade: G0 (<50 microvacuoles per mm(2) ), G1 (50-150 microvacuoles per mm(2) ), and G2 (>150 microvacuoles per mm(2) ). All eyes underwent a best-corrected visual acuity evaluation (BCVA, LogMAR scale), a complete clinical examination, a visual field test, a contrast sensitivity evaluation and a wavefront analysis of high-order aberrations (HOAs) using a Shack-Hartmann aberrometer. Eyes with a posterior capsular opacification and a BCVA>0.30 LogMAR were excluded.

Results: Twenty six eyes (38.8%) had a grade 0, 12 eyes (17.9%) a grade 1 and 29 eyes (43.3%) a grade 2 of glistening severity grade. The mean follow-up after cataract surgery was 35.2 ± 24.2 months and was significantly higher for G1 and G2 groups (p < 0.001). A higher number of topical glaucoma medication were associated with a higher glistening severity grade (p < 0.05). G1 and G2 groups had significantly lower mean contrast sensitivity values at high spatial frequencies and significantly higher loss variance (LV) values of the visual field test (p < 0.05). There was no significant difference in mean BCVA between groups (p = 0.455).

Conclusions: In glaucomatous eyes, glistening increased with time was associated with the number of topical glaucoma medications daily instilled and altered visual performances. It should be a consideration for glaucoma patients who are more likely to develop glistening within the IOL optic.

Keywords: glaucoma; glistening; hydrophobic acrylic material; intra-ocular lens; visual field.

PubMed Disclaimer

Publication types

LinkOut - more resources