Abstract
Optical coherence tomography (OCT) is a cross-sectional, three-dimensional, high-resolution imaging modality that uses low coherence interferometry to achieve axial resolution in the range of 3-20 μm. Two OCT platforms have been developed: time domain (TD-OCT) and spectral (or Fourier) domain (SD/FD-OCT). Visante anterior segment OCT (Carl Zeiss Meditec) is a TD-OCT widely used for anterior segment imaging. The SD-OCT systems with both posterior and anterior segment imaging capabilities include the RTVue, iVue (Optovue), the Cirrus (Carl Zeiss Meditec), and the Spectralis (Heidelberg Engineering, Inc.). Each of the SD-OCTs has a wavelength in the range of 820-879 nm. Anterior segment OCT is a non-contact method providing high resolution tomographic cross-sectional imaging of anterior segment structures. Anterior segment OCT provides qualitative and quantitative assessment of the anterior segment structures important to the pathogenesis and the anatomical variations of glaucoma, and the approach to and success of treatment. We summarize the clinical applications of anterior segment OCT in glaucoma.
Keywords: biometry; glaucoma drainage devices; interferometry; optical coherence tomography; quantitative assessment; resolution; secondary glaucoma.
Copyright © 2014 Elsevier Inc. All rights reserved.
Similar articles
-
[Anterior segment optical coherence tomography in glaucoma].Klin Monbl Augenheilkd. 2008 Mar;225(3):194-9. doi: 10.1055/s-2008-1027241. Klin Monbl Augenheilkd. 2008. PMID: 18351532 Review. German.
-
Comparison of two spectral domain optical coherence tomography devices for angle-closure assessment.Invest Ophthalmol Vis Sci. 2012 Aug 3;53(9):5131-6. doi: 10.1167/iovs.12-10132. Invest Ophthalmol Vis Sci. 2012. PMID: 22786910
-
Retinal nerve fiber layer imaging with spectral-domain optical coherence tomography: a variability and diagnostic performance study.Ophthalmology. 2009 Jul;116(7):1257-63, 1263.e1-2. doi: 10.1016/j.ophtha.2009.04.013. Epub 2009 May 22. Ophthalmology. 2009. PMID: 19464061
-
Slit-lamp-adapted fourier-domain OCT for anterior and posterior segments: preliminary results and comparison to time-domain OCT.Curr Eye Res. 2010 Aug;35(8):722-32. doi: 10.3109/02713683.2010.481069. Curr Eye Res. 2010. PMID: 20673049
-
Development in anterior segment imaging for glaucoma.Curr Opin Ophthalmol. 2014 Mar;25(2):98-103. doi: 10.1097/ICU.0000000000000026. Curr Opin Ophthalmol. 2014. PMID: 24370972 Review.
Cited by
-
Anterior segment optical coherence tomography imaging of conjunctival filtering blebs after glaucoma surgery.Biomed Res Int. 2014;2014:610623. doi: 10.1155/2014/610623. Epub 2014 Jul 20. Biomed Res Int. 2014. PMID: 25136603 Free PMC article. Review.
-
Benefit of Measuring Anterior Segment Structures Using an Increased Number of Optical Coherence Tomography Images: The Chinese American Eye Study.Invest Ophthalmol Vis Sci. 2016 Nov 1;57(14):6313-6319. doi: 10.1167/iovs.16-19755. Invest Ophthalmol Vis Sci. 2016. PMID: 27893097 Free PMC article.
-
Deep learning in glaucoma with optical coherence tomography: a review.Eye (Lond). 2021 Jan;35(1):188-201. doi: 10.1038/s41433-020-01191-5. Epub 2020 Oct 7. Eye (Lond). 2021. PMID: 33028972 Free PMC article. Review.
-
Hand-held optical coherence tomography imaging in children with anterior segment dysgenesis.Acta Ophthalmol. 2017 Aug;95(5):537-541. doi: 10.1111/aos.13053. Epub 2016 Apr 30. Acta Ophthalmol. 2017. PMID: 27130748 Free PMC article. No abstract available.
-
Repeatability and Agreement of Central Vault for Implantable Collamer Lens Obtained by the Tomey OA-2000 Biometer and Spectralis OCT.J Ophthalmol. 2024 Jun 24;2024:3684626. doi: 10.1155/2024/3684626. eCollection 2024. J Ophthalmol. 2024. PMID: 38957378 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical