Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2014 Apr;11(4):373-7.
doi: 10.1016/j.jacr.2013.07.002. Epub 2013 Oct 17.

A quality improvement initiative to reduce unnecessary follow-up imaging for adnexal lesions

Affiliations

A quality improvement initiative to reduce unnecessary follow-up imaging for adnexal lesions

Jamie S Hui et al. J Am Coll Radiol. 2014 Apr.

Abstract

Our objective was to improve the quality of pelvic ultrasound reports and decrease the number of physiologic and benign adnexal lesions unnecessarily referred for follow-up. We performed a prospective cohort study of 2 quality improvement interventions: academic detailing with education for the ultrasound radiologists and sonographers, and implementation of a national consensus guideline on adnexal cysts. Our primary quality outcome measure was the proportion of pelvic ultrasound exams in which follow-up was recommended for an adnexal lesion. Baseline data collection in January 2006 identified 252 pelvic ultrasound exams, of which 58 (23%) reported an adnexal lesion and 31 (12%) recommended follow-up. Retrospective review revealed that 17 of 31 (55%) reported adnexal lesions with follow-up recommended were physiologic or benign. After intervention 1, 59 of 214 (28%) pelvic ultrasound exams from January 2008 reported an adnexal lesion, with 18 (8%) recommending follow-up. After intervention 2, 64 of 296 (22%) pelvic ultrasound exams from January 2011 reported an adnexal lesion, with 16 (5%) recommending follow-up. Follow-up recommendations decreased 58% (12% versus 5%, P = .004), with significant increase in the proportion characterized as physiologic or benign (P = .001). Through a quality initiative aimed at appropriate description and follow-up recommendations for adnexal cystic lesions identified at ultrasound, we effectively reduced unnecessary imaging referrals. We conclude that: (1) acceptance of an expert consensus guideline was important to add credibility, (2) accessible image-rich charts are invaluable tools at point of use, and (3) elimination of some unnecessary imaging is under the control of the radiologist.

Keywords: Adnexal cysts; imaging appropriateness; quality improvement.

PubMed Disclaimer

Comment in

LinkOut - more resources