Re-evaluation of transvenous lead extraction with modified standard technique: a prospective study in 229 patients
- PMID: 24142715
- DOI: 10.1007/s11596-013-1175-y
Re-evaluation of transvenous lead extraction with modified standard technique: a prospective study in 229 patients
Abstract
As new-type powered sheaths are expensive and unavailable, the standard lead extraction techniques remain the mainstay in clinical applications in many countries. The purpose of this study was to re-evaluate the clinical application of the standard lead extraction techniques and equipment, and make some procedural modifications and innovations. In our center, between January 2006 and May 2012, 229 patients (median, 66 years) who underwent lead extraction due to infection and lead malfunction were registered and followed up prospectively with respect to clinical features, reasons for lead extraction, technical characteristics, and clinical prognosis. A total of 440 leads had to be extracted transvenously by using special tools from 229 patients (male, 72.1%). Vegetations ≥1 cm were detected in six patients. Locking Stylets were applied for 398 (90.5%) leads. Telescoping dilator polypropylene sheaths and counter traction technique were used for 202 (45.9%) leads due to lead adhesion, and the mean implant duration of the 202 leads was longer than the other 238 leads (48.9±22.6 vs. 26.6±17.8 months; P <0.01). In addition, modified isolation and snare techniques were used for 56 leads (12.7%). Minor and major procedure-related complications occurred in three (1.3%) and four (1.7%) cases respectively, including one death (0.4%). Severe lead residue occurred in one case. Complete procedural success rate was 96.1% (423/440), and clinical success rate was 98.9% (435/440). The median follow-up period was 18 (1-76) months. No infection- and procedure-related death occurred in our series. Our data demonstrated that high clinical success rate of transvenous lead extraction can be guaranteed by making full use of the standard lead extraction techniques and equipment with individualized modifications.
Similar articles
-
Transvenous extraction of pacing and defibrillator leads--a single-centre experience.Acta Cardiol. 2012 Dec;67(6):641-8. doi: 10.1080/ac.67.6.2184666. Acta Cardiol. 2012. PMID: 23393934
-
Percutaneous extraction of leads from coronary sinus vein and branch by modified techniques.Chin Med J (Engl). 2012 Oct;125(20):3707-11. Chin Med J (Engl). 2012. PMID: 23075729
-
Pacemaker and ICD lead extraction with electrosurgical dissection sheaths and standard transvenous extraction systems: results of a randomized trial.Europace. 2007 Feb;9(2):98-104. doi: 10.1093/europace/eul171. Europace. 2007. PMID: 17272329 Clinical Trial.
-
Extraction of cardiac rhythm devices: indications, techniques and outcomes for the removal of pacemaker and defibrillator leads.Int J Clin Pract. 2010 Jul;64(8):1140-7. doi: 10.1111/j.1742-1241.2010.02338.x. Int J Clin Pract. 2010. PMID: 20642712 Review.
-
Femoral extraction of transvenous leads and leadless pacemakers-A review of the data, tools, and procedural steps.Pacing Clin Electrophysiol. 2019 Sep;42(9):1248-1252. doi: 10.1111/pace.13766. Epub 2019 Aug 5. Pacing Clin Electrophysiol. 2019. PMID: 31355937 Review.
Cited by
-
Comparison of non-laser and laser transvenous lead extraction: a systematic review and meta-analysis.Europace. 2023 Nov 2;25(11):euad316. doi: 10.1093/europace/euad316. Europace. 2023. PMID: 37882609 Free PMC article.
References
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Research Materials