Multicenter Study
. 2014;72(2):140-5.
doi: 10.5603/KP.a2013.0252. Epub 2013 Oct 21.

Long-term follow-up of mesh-covered stent implantation in patients with ST-segment elevation myocardial infarction

Affiliations
Free article
Multicenter Study

Long-term follow-up of mesh-covered stent implantation in patients with ST-segment elevation myocardial infarction

Dariusz Dudek et al. Kardiol Pol. 2014.
Free article

Abstract

Background: The MGuard stent (a bare-metal stent wrapped externally in a polymer mesh sleeve) was introduced to reduce the risk of distal embolisation and no-reflow phenomenon during percutaneous coronary intervention (PCI) in thrombus containing lesions, including ST-segment elevation myocardial infarction (STEMI). However, data on the long-term performance of the MGuard stent is limited.

Aim: To assess the long-term safety and efficacy of MGuard stent implantation during primary PCI for STEMI.

Methods and results: In this multicentre study, a total of 60 patients with STEMI ≤12 h treated with the MGuard stent were enrolled. Angiographic success of PCI was achieved in 96.7%, with the final TIMI grade 3 flow in 90.0% of patients. At six months, the overall rate of major adverse cardiac and cerebrovascular events (MACCE; composite of cardiac death, nonfatal target vessel reinfarction, target lesion revascularisation, and stroke) was 1.7%. A long-term follow-up of the study was successfully performed in 57 patients (mean follow-up of 38.7 ± 3.1 months). The long-term cardiac mortality was 7.0%, with a MACCE rate of 8.8%. There was no decrease in the left ventricular ejection fraction and no enlargement of the left ventriclebetween index and long-term follow-up echocardiogram.

Conclusions: The early safety and efficacy of the MGuard stent was maintained during the long-term follow-up. However, comparative data from ongoing randomised clinical trials are still required to confirm the long-term efficacy of MGuard stent implantation in patients with STEMI.

PubMed Disclaimer

Comment in

Publication types

LinkOut - more resources